Hampton® H15-1 Direct Vent Freestanding Gas Stove 15
H1H

V

Horizontal Venting with Two (2) 90o Elbows
Option V H + H1
A) 1' Min. 3' Max.
B) 2' Min. 4' Max.
C) 3' Min. 5' Max.
D) 4' Min. 6' Max.
E) 5' Min. 7' Max.
F) 6' Min. 8' Max.
Horizontal Venting with Two (2) 90o Elbows
Option H V H + H1
A) 1' Max. 1' Min. 3' Max.
B) 2' Max. 2' Min. 5' Max.
C) 3' Max. 4' Min. 6' Max.
D) 4' Max. 6' Min. 7' Max.
E) 5' Max. 8' Min. 8' Max.
With these options, max.
total pipe length is 30 feet
with min. of 8 feet total
vertical and max. 8 feet
total horizontal.
Please note min. 1 foot
between 90o elbows is
required.
With these options, maxi-
mum total pipe length is 30
feet with minimum of 6 feet
total vertical and maximum
8 feet total horizontal.
Please note minimum 1
foot between 90o elbows
is required.
One 90o elbow = Two 45o elbows.
One 90o elbow = Two 45o elbows.

H

H1
V
Vent restrictor position A (fully open), refer to the "Vent
Restrictor Postion" section.
Vent restrictor position A (fully open), refer to the "Vent
Restrictor Postion" section.
Lengths do not include elbow indicated
Lengths do not include elbow indicated
INSTALLATION