Hampton® H15-1 Direct Vent Freestanding Gas Stove 17
Offset to Vertical Terminations
Venting Arrangements - Horizontal Terminations
VENTING ARRANGEMENTS
Vertical Terminations Systems for
Residential Manufactured and Mobile Homes
The shaded area in the diagram below shows all allowable combinations of straight
vertical and offset to vertical runs with vertical terminations. Maximum two 45o
elbows.
If the vent is ENCLOSED in a chase (min. size 9" x 9") maintain a 1-1/4" clearance to
combustibles.
May be installed in Manufactured (Mobile) Homes after fi rst sale.
Horizontal Terminations for
All Venting Systems
The shaded areas in the diagram below show all
allowable combinations of vertical runs with hori-
zontal terminations. Maximum one 90O elbow (two
45o elbows equal one 90o elbow).
Propane and Natural Gas:
Residential, Manufactured and Mobile
Homes Installations
May be installed in Manufactured (Mobile)
Homes after fi rst sale.
The two diagrams show all allowable com-
binations of straight horizontal termination
with one 45o elbow off the unit. Restrictor
position "A".
12" max. w/AstroCap or Simpson Duravent
Horizontal Square Termination Cap.
24" max. w/FPI Riser or Simpson Duravent
Snorkel Termination Cap.
INSTALLATION