16 Hampton® H15-1 Direct Vent Freestanding Gas Stove
H1HV

Vertical Venting with Two (2) 90o Elbows

Option V H V + V1
A) 1' Min. 4' Max. 2' Min.
B) 2' Min. 5' Max. 3' Min.
C) 3' Min. 6' Max. 4' Min.
D) 4' Min. 7' Max. 5' Min.
E) 5' Min. 8' Max. 6' Min.

Vertical Venting with Two (2) 90o Elbows

With these options, max. total
pipe length is 30 feet with min.
of 6 feet total vertical and max.
8 feet total horizontal.
Please note min. 1 foot
between 90o elbows is re-
quired.
Option H + H1 V
A) 2' Max. 2' Min.
B) 3' Max. 3' Min.
C) 4' Max. 4' Min.
D) 5' Max. 5' Min.
E) 6' Max. 6' Min.
With these options, max. total
pipe length is 30 feet with min.
of 6 feet total vertical and max.
6 feet total horizontal.
Please note min. 1 foot
between 90o elbows is
required.
One 90o elbow = Two 45o elbows.
One 90o elbow = Two 45o elbows.

V1

V

H

Vent restrictor position A (fully open), refer to the "Vent
Restrictor Postion" section.
Vent restrictor position A (fully open), refer to the
"Vent Restrictor Postion" section.
Lengths do not include elbow indicated
Lengths do not include elbow indicated
INSTALLATION