18 Hampton® H15-1 Direct Vent Freestanding Gas Stove

Venting Arrangements - Vertical Terminations

with Co-linear Flex System for both

Residential & Manufactured Homes

into Masonry Fireplaces

The shaded area in the diagram shows the allowable vertical
terminations.
VERTICAL TERMINATION WITH CO-LINEAR FLEX SYSTEM
THE APPLIANCE MUST NOT BE
CONNECTED TO A CHIMNEY FLUE
SERVING A SEPARATE SOLID FUEL
BURNING APPLIANCE.
This appliance is designed to be attached to
two 3" (76mm) co-linear aluminium fl ex running
the full length of the chimney. See the Venting
Arrangements chart below for minimum and
maximum fl ue lengths. See chart below for
minimum distances from roof. Periodically check
that the vent is unrestricted.
Masonry chimneys may take various contours which the fl exible liner will accommodate. However,
keep the fl exible liner as straight as possible, avoid unnecessary bending.
The Air Intake pipe must be attached to the inlet air collar of the termination cap.

Straight Vertical Terminations

Required Parts:

Part # Description
946-529 Co-linear DV Vertical
Termination Cap
948-305 3" Flex - 35 ft.
946-563 Co-Axial to Co-Linear Adapter
Kit
which contains the following:
Co-linear Flex Adapter (270-585)
Outer Pipe (946-257)
Inner Pipe Adapter (946-219)
Alternate Approved Caps
980 Vertical Termination Cap
991 High Wind Cap
923GK
3" Co-linear Adapter with ashing
Vent Restrictors
set at fully closed,
Position "B"
INSTALLATION