Harbor Freight Tools 68332 manual PTZ Setup Pan/Tilt/Zoom, Mobile

Models: 68332

1 37
Download 37 pages 23.4 Kb
Page 19
Image 19

Note: To save changes, you must press APPLY.

PTZ Setup (Pan/Tilt/Zoom)

(PTZ cameras not included)

Click [Main Menu→Device→ PTZ Setup] to enter the PTZ Setup menu.

Select the channel you want to control and set PTZ protocol (Pelco-D or Pelco-P), Baud Rate (1200, 2400, 4800, 9600), Stop bit (1, 2), Parity Check (None, Odd, Even Mark Space), and Address Code.

Note: The above mentioned channel settings must match the settings of the PTZ camera.

Set CRUISE to ON to enter the sub menus that adjust the individual camera settings.

Click Z+&Z- keys to zoom In or out, click F+&F- keys to control camera focus and click I+&I- to adjust iris.

CRUISE SETUP

Click CRUISE SET to open the auto cruise function window if you want to adjust the cruise function. The system default is ON.

CH#: Select the channel number with the PTZ camera

TOTAL: Enter presetting bit quantity.

CUR POINT: System has default starting (current) cruise point as 01. You can use this option to set additional cruise points.

STOP TIME: Adjust the pause time at each stop.

GOTO: Select this option to go to specific preset points.

SET: Saves the preset point. After setting channel and setting the position by adjusting PTZ direction key click SET to setup the pre-set point. Please note you need to click SAVE to finish the setup successfully. If you want to combine Zoom, Iris, Focus and direction keys into the pre-set setting, return to previous menu to add additional settings, and then enter into Cruise Set again and click SET and SAVE to make sure your setting is setup successfully.

CLEAN: Removes settings.

Note: This DVR model supports up to 100 pre- set points. But actual quantities may be restricted by the PTZ camera you are using.

Mobile

Click [Main menu→Device→Mobile] to enter into [Mobile] menu.

USER NAME: Enter the user name of the DVR.

USER PASSWORD: Enter the user password of the DVR.

SERVER PORT: Enter the mobile monitoring port. Setting range is between 1024 and 65535.

Note: Connect the DVR to the Internet before setting the DVR port number and the server port number. Consult your mobile provider for additional information.

SKU 68332

For technical questions, please call 1-800-444-3353

Page: 16

Page 19
Image 19
Harbor Freight Tools 68332 manual PTZ Setup Pan/Tilt/Zoom, Mobile