Solution 2: Move the drum to its home position. To do this, run FlexColor and select Maintenance > Feeder to open the Feeder window. Then set the Drum position drop-down list to “home”. Try scanning again.

Solution 3: Make sure that the magazine is pressed fully into the drawer hinge. See also “Loading Slides” on page 18.

Solution 4: Check that light is not shining directly into the scanner. The Feeder uses an optical system to monitor the position of the original holder; this system can be confused if outside light is shining directly into the scanner.

Solution 5: Check the alignment of the Feeder to make sure the slide original holder is centered. See “Aligning the Feeder” on page 30.