TROUBLESHOOTING

TROUBLESHOOTING

Most treadmill problems can be solved by following the simple steps below. Find the symptom that applies, and follow the steps listed. If further assis- tance is needed, see the front cover of this manual. SYMPTOM: The power does not turn on

a.Make sure that the power cord is plugged into a surge suppressor and that the surge suppressor is plugged into a properly grounded outlet (see page 15). Use only a single-outlet surge suppressor that meets all of the specifications described on page 15. IMPORTANT: The treadmill is not compati- ble with GFCI-equipped outlets and may not be compatible with AFCI-equipped outlets.

b.After the power cord has been plugged in, make sure that the key is inserted into the console.

c.Check the power switch located on the treadmill frame near the power cord. If the switch protrudes as shown, the switch has tripped. To reset the power switch, wait for five minutes and then press the switch back in.

c

Tripped

Reset

SYMPTOM: The power turns off during use

a.Check the power switch (see the drawing above). If the switch has tripped, wait for five minutes and then press the switch back in.

b.Make sure that the power cord is plugged in. If the power cord is plugged in, unplug it, wait for five minutes, and then plug it back in.

c.Remove the key from the console, and then reinsert it.

d.If the treadmill still will not run, please see the front cover of this manual.

SYMPTOM: The console displays remain lit when you remove the key from the console

a.The console features a display demo mode, de- signed to be used if the treadmill is displayed in a store. If the displays remain lit when you remove the key, the demo mode is turned on. To turn off the demo mode, hold down the Stop button for a few seconds. If the displays are still lit, see THE INFORMATION MODE on page 23 to turn off the demo mode.

SYMPTOM: The displays of the console do not function properly

a.Remove the key from the console and UNPLUG THE POWER CORD. Remove the five #8 x 3/4" Screws (2) and carefully pivot the Motor Hood (18) off.