Hearth and Home Technologies COLBAY-FS-B Gas Information, Fuel Conversions, Converting to LP Gas

Models: COLBAY-FS-B

1 49
Download 49 pages 20.93 Kb
Page 22
Image 22

6 Gas Information

A. Fuel Conversions

Before making gas connections ensure that the appliance being installed is compatible with the available gas type.

Any natural or propane gas conversions necessary to meet the appliance and locality needs must be made by a quali- fied technician using Hearth & Home Technologies specified and approved parts.

1. Converting to LP Gas

NOTE: Gas conversions should only be performed by a qualified service person, and/or where required by state and local codes, licensed installer/service technician. In the Commonwealth of Massachusetts, installation must be performed by a licensed plumber or gas fitter.

KIT CONTENTS: Replacement orifice; replacement pilot injector; valve regulator; conversion label.

TOOLS REQUIRED: Power drill (a 90° handle is helpful); #2 Phillips bit; 5/32 in. Allen wrench; 5/8 in. open-end wrench.

Disconnect power and turn off gas supply if installed.

Remove the front, glass, brick refractory and logs if installed. (It is only necessary to remove the left brick panel for burner removal. The metal brick refractory does not need to be removed.)

Opens Left Closes Right

Figure 6.1 Loosen the shutter adjustment nut (located under- neath the appliance) with a 7/16 in. wrench.

It is helpful to remove the nut completely. Slide the shutter to the right (closed position).

Figure 6.2 Lift the burner from the left side and slide left until free from the orifice receiver. Remove from the firebox and handle with care.

Figure 6.3 With a 5/8 in. wrench remove orifice retaining nut. Replace with appropriate orifice.

PROPANE

NATURAL GAS

.0635 (52 DMS)

.1065 (36 DMS)

If the shutter is removed with the burner as indicated in Figure 6.2, it must be reinstalled over the orifice prior to the reinstallation of the burner.

Figure 6.4 Remove the pilot hood, and set aside. Using a 5/32 in. allen wrench, remove the pilot injector and replace with an appropriate injector (35 LP, 62 NG).

Reinstall the burner, and reassemble the appliance.

Page 22

Quadra-Fire • Columbia Bay • 250-5195 Rev. K

10/08

Page 22
Image 22
Hearth and Home Technologies COLBAY-FS-B owner manual Gas Information, Fuel Conversions, Converting to LP Gas