Step 8. Wiring the Fireplace

NOTE: Electrical wiring must be installed by a licensed electrician.

For Standing Pilot Ignition Wiring

Appliance Requirements

Optional Accessories

Optional remote control kits require that 230 VAC be wired to the facto- ry installed junction box before the fireplace is permanently installed.

Wall Switch

Position the wall switch in the desired position on a wall. Run a maximum of 780cm or less length of 0.102 cm diameter minimum wire and connect it to the fireplace ON/OFF switch pigtails.

!WARNING: DO NOT CONNECT 230 VAC TO THE GAS CONTROLVALVE

OR THE APPLIANCE WILL MALFUNC- TION AND THE VALVE WILL BE DE- STROYED.

CAUTION: LABEL ALL WIRES PRIOR TO DIS- CONNECTION WHEN SERVICING CON- TROLS. WIRING ERRORS CAN CAUSE IM- PROPER AND DANGEROUS OPERATION. VERIFY PROPER OPERATION AFTER SER- VICING.

Step 9. Finishing

Figure 30 shows the minimum vertical and corresponding maximum horizontal dimensions of fireplace mantels or other combustible projections above the top front edge of the fireplace. See Figures 4 and

5for other fireplace clearances. Only non-combustible materials may be used to cover the black fireplace front.

!

WARNING: WHEN FINISHING THE FIREPLACE, NEVER

OBSTRUCT OR MODIFY THE AIR INLET/OUTLET GRILLES

 

IN ANY MANNER.

 

 

CAUTION: IF JOINTS BETWEEN THE FIN- ISHED WALLS AND THE FIREPLACE SUR- ROUND (TOP AND SIDES) ARE SEALED, A 150° C. MINIMUM SEALANT MATERIAL MUST BE USED. THESE JOINTS ARE NOT REQUIRED TO BE SEALED. ONLY NON- COMBUSTIBLE MATERIAL (USING 150° C.

MINIMUM ADHESIVE, IF NEEDED) CAN BE APPLIED AS FACING TO THE FIREPLACE SURROUND (SEE FIGURE 31).

 

MANTEL

305mm

 

 

280mm

 

254mm

 

228mm

 

 

204mm

 

 

178mm

 

 

153mm

407mm

 

127mm

 

381mm

102mm

356mm

 

 

77mm

 

331mm

51mm

 

305mm

280mm

25.4mm

254mm

 

 

229mm

 

 

204mm

 

 

178mm

 

153mm

 

127mm

 

 

HOOD

NOTE: 305mm (12 in.) mantel at 407mm (16 in.) above hood.

Figure 30.

Minimum Vertical and Maximum Horizontal

Dimensions of Combustibles above Fireplace

NOTE: Sheetrock or other combustible material such as wood can be placed on the top edge and sides of the fireplace.

 

ST-HVB-CE

 

TOP EDGE

 

SIDE EDGE

 

0” GAP

PIER-HVB-CE and L&RCOR-HVB-CE

 

TOP EDGE

 

SIDE EDGE

 

0” GAP

Figure 31.

Sealant Material

34

Heat & Glo • PIER/ST/L&RCOR-HVB-CE2068-900 Rev. H • 6/07

Page 34
Image 34
Hearth and Home Technologies LCOR-HVB-CE, RCOR-HVB-CE Wiring the Fireplace, Finishing, Optional Accessories, Wall Switch