NATURAL GAS

 

 

PROPANE / BUTANE

 

 

 

FLUEING WITH THREE 90° ELBOWS

 

FLUEING WITH THREE 90° ELBOWS

 

 

V + V1 (FT.)

H + H1 (FT.)

 

V + V1 (FT.)

H + H1 (FT.)

 

 

1' MIN. (305mm)

3' MAX. (914mm)

1' MIN. (305mm)

2' MAX. (610mm)

 

 

2' MIN. (610mm)

6' MAX.

(1.83m)

 

2' MIN. (610mm)

4' MAX.

(1.22m)

 

 

3' MIN. (914mm)

9' MAX.

(2.7m)

 

3' MIN. (914mm)

6’ MAX. (1.83m)

 

 

4' MIN. (1.22m)

12' MAX.

(3.6m)

 

4' MIN. (1.22m)

8' MAX.

(2.4m)

 

 

5’ MIN. (1.5m)

15’ MAX.

(4.5m)

 

5’ MIN. (1.5m)

10' MAX.

(3.0m)

 

 

V+ V1 + H + H1 = 36’ MAX. (10.9m)

 

V+ V1 + H + H1 = 36’ MAX. (10.9m)

 

 

H + H1 = 15’ MAX. (4.5m)

 

H + H1 = 10’ MAX. (3.0m)

V1

 

 

 

 

 

 

 

 

 

 

 

V

 

 

 

 

 

 

H1

 

 

 

 

 

 

 

 

 

 

H

 

 

 

 

 

 

 

 

 

 

 

V

 

 

 

H2

 

 

 

 

 

 

 

 

 

 

 

H1

 

 

 

 

 

 

 

 

 

 

H

 

 

NATURAL GAS

 

PROPANE / BUTANE

 

 

 

FLUEING WITH THREE 90° ELBOWS

FLUEING WITH THREE 90° ELBOWS

 

 

V + V1 (FT.)

H + H1 + H2 (FT.)

V + V1 (FT.)

 

H + H1 + H2 (FT.)

 

 

1' MIN. (305mm)

3' MAX. (914mm)

1' MIN. (305mm)

 

2' MAX. (610mm)

 

 

2' MIN. (610mm)

6' MAX.

(1.83m)

2' MIN. (610mm)

 

4' MAX.

(1.22m)

 

 

3' MIN. (914mm)

9' MAX.

(2.7m)

3' MIN. (914mm)

 

6’ MAX. (1.83m)

 

 

4' MIN. (1.22m)

12' MAX.

(3.6m)

4' MIN. (1.22m)

 

8' MAX.

(2.4m)

 

 

V+ V1 + H + H1 + H2 = 36’ MAX. (10.9)

V+ V1 + H + H1 + H2 = 36’ MAX. (10.9)

 

 

H + H1 + H2 = 12’ MAX. (3.6m)

H + H1 + H2 = 8’ MAX. (2.4m)

 

 

Figure 15. Flueing with three 90° elbows

 

 

 

 

 

 

 

Heat & Glo • PIER/ST/L&RCOR-HVB-CE2068-900 Rev. H • 6/07

 

25

Page 25
Image 25
Hearth and Home Technologies PIER-HVB-CE, RCOR-HVB-CE, LCOR-HVB-CE, ST-HVB-CE manual Flueing with three 90 elbows