8 Chimney Assembly

8 Chimney Assembly

NOTICE: Chimney performance may vary.

Trees, buildings, roof lines and wind conditions affect performance.

Chimney height may need adjustment if smoking or overdraft occurs.

Chimney must extend beyond combustible roof structure

Maintain minimum height of chimney above roof

Install roof flashing according to minimum requirements

Offsets/returns may not exceed 30° from vertical

Lock chimney sections together firmly to resist movement

Termination Cap

Additional support for tall chimneys

Storm Collar

Maintain minimum clearances to combustibles as specified

Support straps for offsets (not shown) must be secured to adequate framing

Offsets/returns must be secured with the screws provided (outer pipe only)

Attic shield not shown (see Figure 6.2)

Ceiling firestops are required where chimney passes through ceiling or floor

This fireplace has been tested and listed for use with 14-in. DuraChimney II only.

Figure 8.1 Typical Chimney System - Guidelines for Chimney System Installation

Heat & Glo • RUTHERFORD-504059-333 Rev F • 11/08