E. Install Outside Air Kit
Heat & Glo • RUTHERFORD-504059-333 Rev F • 11/08

3 ft min. from top of uppermost chimney section to air inlet.

Outside air installed on both sides (right side not shown)

Figure 7.3 Outside Air Inlet Locations

NO

NO

 

Garage or

NO

Outlet blocked by

combustible

snow, leaves, etc.

liquids storage

Attic space

 

 

NO

 

 

Outlet placed

 

 

higher than 3 ft

 

 

below the

 

 

termination cap

YES

Factory-built

Clear area

fireplace

 

outside

 

 

 

house or in

 

 

ventilated

 

 

crawl space

 

 

Figure 7.4 Outside Combustion Air Placement

E. Install Outside Air Kit

Keep duct runs short and straight to minimize restriction.

The outside air kits must be installed on both sides of the fireplace.

WARNING! Outside air kits must be installed on both sides of the fireplace to prevent overheating and fire.

Install as shown in Figures 7.3, 7.4 and 7.5.

The air ducts may be run vertically.

The outside air hoods must be at least 3 ft (.91 m) below the top of the uppermost chimney section.

CAUTION! Risk of Fire or Asphyxiation! Do not draw outside combustion air from wall, floor or ceiling cavity, or enclosed spaces such as an attic or garage.

DO NOT place outside air hoods close to exhaust vents or chimneys. Fumes or odor could be drawn into the room through the fireplace.

Locate outside air hoods to prevent blockage from leaves, snow/ice, or other debris. Blockages could cause the unit to overheat.

NOTICE: The fireplace provides some outside air for combustion. Other methods may be necessary if more air is required.

22

Flexible Duct (not supplied)

Outside Air

 

Hood

2 Wire Ties

Figure 7.5 Outside Air Installation