G. Assemble Chimney Sections
Attach the first chimney section or offset onto the top of the fireplace (Figure 8.4). Sheet metal screws are required to connect Chimney Section to Anchor Plate. Continue to add additional sections of chimney as needed. Use a Wall Strap every eight (8) feet of chimney height. For each additional Chimney Section use (4) sheet metal screws provided, to make a secure connection between the chimney sections (Figure 8.5). Do not penetrate the inner liner of the chim- ney.
H. Supplementary Support and Stabilizer
If additional support is needed, install one or more Sup- plementary Supports which can each support
Figure 8.4
Install supplementary support if height exceeds 50 ft or if required by fireplace manufacturer
Figure 8.6
Each supplementary support holds up to 25 ft. of chimney
Maintain 2 in. clearance from chimney to framing
Figure 8.5
Chase
Frame
Stabilizer
Plumbers
Tape
Figure 8.7
26 | Heat & Glo • |