Hearth and Home Technologies RUTHERFORD-50 owner manual B. Install Fireplace & Chimney, 6 in. Min

Models: RUTHERFORD-50

1 52
Download 52 pages 33.52 Kb
Page 31
Image 31
B. Install Fireplace & Chimney

B. Install Fireplace & Chimney

Install as per Sections 7 and 8.

C. Install Chase Top Flashing

You MUST use a chase top flashing in a chase installation. Chase top flashings are available from your Heat & Glo dealer or may be field constructed.

For chase enclosures, use a chase top flashing. The chase top flashing allows for a 1 1/2 in. (38 mm) clearance around the outside of the chimney pipe for ventilation air. Install the chase top flashing at the top of the chase with a 1/2 in. (13

mm)air clearance off the top of the chase constructions (Figure 9.4, 9.5). Use spacing clips to ensure the 1/2 in.

(13 mm) air clearance. If the chase top flashing does not fit the dimensions of the chase, a custom flashing can be field-fabricated as long as it has the same dimensions as noted in Figure 10.1. Secure the chase top flashing to the chase with at least three screws or nails per side. When installed, the bottom of the termination cap must be at least 6 in. (152 mm) above the chase top flashing (Figure 9.6).

1

1/2

 

Figure 9.5 Chase Top Construction

6 in. Min.

1/2 in. air space established by spacers

1/2 in.

Air Space

Storm collar must

be installed 1 1/2 in.

off chase top

Chase Top

Flashing

Figure 9.6 Chase Top Construction

D. Install Termination Cap

Install the chimney sections up through the chase enclo- sure.

(Not furnished by

Dura-Vent) Fabricated

Spaces Locally

Figure 9.4 Chase Top Construction

C. Install Chase Top Flashing1/2

Install termination caps following instructions provided with them.

WARNING! Risk of Fire! The minimum overlap of cap to pipe (as shown in the following illustrations) MUST be met or chimney may separate from cap. Separation al- lows sparks, heat and embers to escape.

NOTICE: Paint the termination cap with a rust-resistant paint to protect against the effects of corrosion on those parts exposed to the weather.

Heat & Glo • RUTHERFORD-504059-333 Rev F • 11/08