B. Install Fireplace & Chimney
Install as per Sections 7 and 8.
C. Install Chase Top Flashing
•You MUST use a chase top flashing in a chase installation. Chase top flashings are available from your Heat & Glo dealer or may be field constructed.
For chase enclosures, use a chase top flashing. The chase top flashing allows for a 1 1/2 in. (38 mm) clearance around the outside of the chimney pipe for ventilation air. Install the chase top flashing at the top of the chase with a 1/2 in. (13
mm)air clearance off the top of the chase constructions (Figure 9.4, 9.5). Use spacing clips to ensure the 1/2 in.
(13 mm) air clearance. If the chase top flashing does not fit the dimensions of the chase, a custom flashing can be
1 | 1/2 |
|
Figure 9.5 Chase Top Construction
6 in. Min.
1/2 in. air space established by spacers
1/2 in.
Air Space
Storm collar must
be installed 1 1/2 in.
off chase top
Chase Top
Flashing
Figure 9.6 Chase Top Construction
D. Install Termination Cap
Install the chimney sections up through the chase enclo- sure.
(Not furnished by
Spaces Locally
Figure 9.4 Chase Top Construction
1/2
•Install termination caps following instructions provided with them.
WARNING! Risk of Fire! The minimum overlap of cap to pipe (as shown in the following illustrations) MUST be met or chimney may separate from cap. Separation al- lows sparks, heat and embers to escape.
NOTICE: Paint the termination cap with a
Heat & Glo • | 31 |