Step 2. Framing the Fireplace

Fireplace framing can be built before or after the fireplace is set in place. Framing should be positioned to accommo- date wall coverings and fireplace facing material. The dia- gram below shows framing reference dimensions.

CAUTION: MEASURE FIREPLACE DIMENSIONS AND VERIFY FRAMING METHODS AND WALL COVERING DETAILS BEFORE FRAMING.

Framing should be constructed of 2 X 4 lumber or heavier.

Noncombustible zone is defined by 3” above the elbow for the entire width and depth (behind the front header) of the firebox.

WALL

3

STUD

B

C

A

3 1/2”

 

A.

.............

42”*

B.

......... 38

1/2”

C.

...............

22”

D.

......... 42

3/4”

E.

......... 27

7/8”

E D

Shows center of 10” x 12” vent framing holes for top and rear venting. The center of the hole is one (1) inch (25.4mm) above the center of the horizontal vent pipe.

Figure 3. Framing Dimensions

1/2” CLEARANCE FROM BACK OF FIREPLACE TO COMBUSTIBLE

1/2” CLEARANCE FROM BOTH SIDES OF FIREPLACE TO COMBUSTIBLE

FRAMING

MEMBER

0” CLEARANCE

0” CLEARANCE TO

FRAMING MEMBER

12

Heat & Glo • 6000TRI-IPI, 6000TRI-SP385-901 Rev. F • 5/05

Page 12