Step 5. Installing the Optional Heat-Zone Kit
NOTE: There must be NO INSULATION or other com- bustibles inside the framed firestop opening.
ATTACHES |
HERE |
Figure 32. |
1.Remove the knockout from the fireplace and discard it (see Figure 32).
2.Center the duct collar around the exposed hole and at- tach it to the fireplace with 3 screws. NOTE: Do this BE- FORE final positioning of the fireplace.
3.Determine the location for the air register/fan housing assembly.
Reference the
Step 6. The Gas Control Systems
!WARNING: THIS UNIT IS NOT FOR USE WITH SOLID FUEL.
The types of gas control systems used with this model are Intermittent Pilot Ignition (IPI) and Standing Pilot Ignition (SP).
Intermittent Pilot Ignition (IPI) System
This system includes a 3V control valve, electronic module and intermittent pilot.
!WARNING: CONTINUOUS
VICE MUST BE WIRED DIRECTLY TO THE FIRE- PLACE JUNCTION BOX.
FLAME SENSOR
ROD
Figure 33. Gas Control System (IPI)
Standing Pilot Ignition System
This system includes millivolt control valve, standing pilot, thermopile/thermocouple flame sensor, and piezo ignitor.
WARNING:
MILLIVOLT SYSTEM.
Figure 34. Gas Control System (Standing Pilot)