3.Match the amount of vertical you have in the sys- tem with the chart to find the appropriate position to set the Flue Restrictor (see Figure 9).

- CHART -

Vertical

Top Vent

Top Vent

Rear Vent

Rear Vent

NG

LP

NG

LP

 

4'

1-1

No

No

No

Restrictor

Restrictor

Restrictor

 

 

8'

2-2

1-2

1-1

No

Restrictor

 

 

 

 

15'

3-3

3-2

2-2

1-2

 

 

 

 

 

20'

3-4

3-3

3-3

2-3

 

 

 

 

 

25'

3-4

3-3

3-3

2-3

 

 

 

 

 

30'

4-4

3-4

3-4

3-3

 

 

 

 

 

35'

4-4

3-4

3-4

3-3

 

 

 

 

 

40'

5-4

4-4

4-4

3-4

 

 

 

 

 

Figure 9

4. Center the Flue Restrictor on vent and secure in place by using two self-tapping screws.

5. Reinstall the Exhaust Shield.

1 2 3 4 5

SETTINGS

1 2 3 4 5

Figure 10

HORIZONTAL VENTING

Kit No.

H Max. Run

DVP-TRAP

24" (610 mm)

H

90-DEGREE ELBOWS

45-DEGREE

ELBOW

NOTE: This model is tested and approved to use 45° elbows in corner installations. However, 90° elbows will result in better performance. The use of two 900 elbows in a corner installation will affect space requirements (see Figure 2).

Figure 11. Corner Installation