I

INTERMITTENT

PLUG-IN

 

 

 

IGNITION MODULE

 

PILOT

 

 

 

3 VAC

 

 

IGNITOR

3V TRANSFORMER

 

 

 

 

 

 

 

 

 

 

 

 

ON/OFF

 

 

 

 

 

S

 

WALL

 

 

 

 

 

 

SWITCH

 

 

 

 

 

 

 

 

 

FLAME SPARKER/

 

 

 

 

 

 

SENSOR

 

 

 

 

 

IGNITION

 

 

 

 

 

 

 

MODULE

 

 

 

 

 

 

 

(3V)

 

 

 

 

 

 

 

 

 

 

 

 

 

WHT

 

 

 

 

 

 

 

ORG

 

VALVE

LOW VOLTAGE

 

 

 

GROUND TO

 

 

SEE NOTE 1

 

 

 

FIREPLACE

 

 

 

 

 

 

 

CHASSIS

 

GROUND

REMOTE

 

 

 

 

 

NEUTRAL

 

CONTROL

HOT

 

 

BRN

 

 

 

 

 

 

BRN

 

 

 

WHITE WIRE

 

 

 

 

 

 

CAN BE

 

 

ORG

 

 

 

PLUGGED

 

 

 

 

 

INTO ANY

 

 

GRN

BLACK WIRE CAN BE

 

OF #1-#5

 

 

PLUGGED INTO ANY OF

 

LOCATIONS

 

PIGGYBACK

 

#1 - #5 LOCATIONS

 

ON THE

 

ON/OFF SWITCH

 

ON THE HOT SIDE

 

NEUTRAL SIDE

TRANSFORMER

 

 

 

 

 

 

 

3 VAC

 

 

 

 

 

 

PLUG IN

 

 

 

 

 

 

 

 

 

 

VALVE

 

Figure 36. Intermittent Pilot Ignition (IPI) Wiring Diagram

 

 

 

3/16” PIGGYBACK CONNECTOR

 

REMOTE SWITCH

BLACK S2

PIGTAIL

 

 

ON

 

 

 

OFF

 

 

TH

ON/OFF

 

 

TP

 

 

WHITE T2

SWITCH

 

GAS VALVE

RED T1

 

 

 

 

 

 

THERMOPILE

 

 

THERMOCOUPLE

 

BLACK S1

OPTIONAL WALL SWITCH,

 

 

 

 

 

 

THERMOSTAT OR REMOTE

Figure 37. Standing Pilot (SP) Ignition Wiring Diagram

 

 

 

Heat & Glo • 6000TRI-IPI, 6000TRI-SP385-901 Rev. F • 5/05

29

Page 29
Image 29
Heat & Glo LifeStyle 6000TRI-SP, 6000TRI-IPI manual Intermittent Pilot Ignition IPI Wiring Diagram