| I | INTERMITTENT |
|
|
| IGNITION MODULE |
| PILOT | ||
|
|
| 3 VAC |
|
| IGNITOR | |
3V TRANSFORMER |
|
|
|
|
| ||
|
|
|
|
|
|
| |
ON/OFF |
|
|
|
|
| S |
|
WALL |
|
|
|
|
|
| |
SWITCH |
|
|
|
|
|
|
|
|
| FLAME SPARKER/ |
|
|
|
| |
|
| SENSOR |
|
|
|
|
|
IGNITION |
|
|
|
|
|
|
|
MODULE |
|
|
|
|
|
|
|
(3V) |
|
|
|
|
|
|
|
|
|
|
|
|
| WHT |
|
|
|
|
|
|
| ORG |
|
VALVE | LOW VOLTAGE |
|
|
| GROUND TO |
| |
| SEE NOTE 1 |
|
|
| FIREPLACE |
| |
|
|
|
|
|
| CHASSIS |
|
GROUND | REMOTE |
|
|
|
|
| |
NEUTRAL |
| CONTROL | HOT |
|
| BRN |
|
|
|
|
|
| BRN |
| |
|
| WHITE WIRE |
|
|
|
| |
|
| CAN BE |
|
| ORG |
| |
|
| PLUGGED |
|
|
| ||
|
| INTO ANY |
|
| GRN | ||
BLACK WIRE CAN BE |
| OF |
|
| |||
PLUGGED INTO ANY OF |
| LOCATIONS |
| PIGGYBACK |
| ||
#1 - #5 LOCATIONS |
| ON THE |
| ON/OFF SWITCH |
| ||
ON THE HOT SIDE |
| NEUTRAL SIDE | TRANSFORMER |
|
|
| |
|
|
|
| 3 VAC |
|
|
|
|
|
| PLUG IN |
|
|
|
|
|
|
|
|
|
| VALVE |
|
Figure 36. Intermittent Pilot Ignition (IPI) Wiring Diagram |
|
|
|
3/16” PIGGYBACK CONNECTOR |
| REMOTE SWITCH | |
BLACK S2 | PIGTAIL | ||
|
| ON |
|
|
| OFF |
|
| TH | ON/OFF |
|
| TP |
| |
| WHITE T2 | SWITCH |
|
GAS VALVE | RED T1 |
|
|
|
|
| |
| THERMOPILE |
|
|
THERMOCOUPLE |
| BLACK S1 | OPTIONAL WALL SWITCH, |
|
|
| |
|
|
| THERMOSTAT OR REMOTE |
Figure 37. Standing Pilot (SP) Ignition Wiring Diagram |
|
| |
| Heat & Glo • | 29 |