Step 9. Wiring the Fireplace
Intermittent Pilot Ignition (IPI) Wiring
3 Volt Transformer
This appliance comes with a 3 volt transformer found in the manual bag. Plug the transformer leads to the green con- trol module (see Figure 36). Then plug the transformer into the side outlet on the junction box.
Appliance Requirements
•This appliance DOES NOT require
!WARNING: DO NOT CONNECT
NOTE: Electrical wiring must be installed by a licensed electrician.
CAUTION: DISCONNECT REMOTE CONTROLS IF AB- SENT FOR EXTENDED TIME PERIODS. THIS WILL PRE- VENT ACCIDENTAL FIREPLACE OPERATION.
For Standing Pilot Ignition Wiring (see Figure 37). Appliance Requirements
•This appliance DOES NOT require
!WARNING: DO NOT CONNECT
Optional Accessories
Optional fan and remote control kits require that
Wall Switch
Position the wall switch in the desired position on a wall. Run a maximum of 25 feet (7.8 m) or less length of 18 A.W.G. minimum wire and connect it to the fireplace ON/ OFF switch pigtails.
CAUTION: LABEL ALL WIRES PRIOR TO DISCONNEC- TION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPERAND DANGEROUS OPERATION. VERIFY PROPER OPERATION AFTER SERVICING.
Operation using Battery Power
This fireplace has an optional battery operation. The sys- tem is fully functional with the use of two “D” size batteries without ordinary
Wiring to the battery pack should be left disconnected in order to conserve battery life. In the case of a loss of power, simply connect red and black wire leads to activate battery power (connect red to red, black to black). The fireplace can be used as necessary. Once power (110 VAC) is re- stored, disconnect red and black wire leads to extend bat- tery life.
| VARIABLE SPEED CONTROL |
| |
BLK | BLK | JUNCTION BOX |
|
|
| ||
|
|
| |
|
| BLK |
|
BLK |
|
| BLK |
|
|
| |
BLK |
| BLK |
|
|
| WHT | WHT |
|
| BLK |
|
|
| GROUND |
|
TEMPERATURE |
|
|
|
SENSOR SWITCH |
| GRN |
|
|
|
| |
|
| BLK | WHT |
|
|
|
BLOWER
NOTE: IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE MUST BE REPLACED, IT MUST BE REPLACED WITH TYPE 105OC RATED WIRE.
BLOWER RECEPTACLE
BLOWER
SENSOR
SWITCH
“FAN”
RECEPTACLE SPEED CONTROL
Figure 38. Fan Wiring Diagram
30 | Heat & Glo • |