Step 2

Positioning,

Leveling, and

Securing the

Insert

Step 3

The Gas Control

Systems

1.Place the insert into position.

2.Level the insert from side to side and from front to back.

If necessary use the legs included in the manual bag. Screw the legs into the nuts installed in the bottom rear of the insert. Turn legs in until insert is level.

WARNING

THIS UNIT IS NOT FOR USE WITH

SOLID FUEL.

The gas control systems used with this model is Standing Pilot Ignition.

Standing Pilot Ignition System

This system includes millivolt control valve, standing pilot, thermopile/thermocouple flame sensor, and piezo ignitor.

WARNING

110-120 VAC MUST NEVER BE CONNECTED TO A CONTROL VALVE IN A MILLIVOLT SYSTEM.

STANDING PILOT

3/8" (10 mm)

Figure 6. Gas Controls Systems

10

Page 13
Image 13
Heat & Glo LifeStyle AT-GRAND manual Standing Pilot Ignition System, Gas Controls Systems