D. Vent Diagrams
WARNING
Fire Risk. Explosion Risk.
Do NOT pack insulation or other combustibles between ceiling firestops.
•ALWAYS maintain specified clearances around venting and firestop systems.
•Install wall shield and ceiling firestops as specified.
Failure to keep insulation or other material away from vent pipe may cause fire.
1. Top Vent - Horizontal Termination
One Elbow | V1 Minimum | H1 | Maximum | ||
Elbow only | 2 ft | 610 mm | |||
| |||||
| 6 in | 152 mm | 2 ft | 610 mm | |
| 1 1/2 ft | 457 mm | 3 ft | 914 mm | |
| 2 1/2 ft | 762 mm | 5 ft | 1.5 m | |
| 3 1/2 ft | 1067 mm | 7 ft | 2.1 m | |
V1 | 4 1/2 ft | 1.4 m | 15 ft | 4.6 m | |
V1 + H1 = 38 ft (11.6 m) Maximum | |||||
H1 |
| H1 = 15 ft (4.6 m) Maximum |
Figure 5.3
Two Elbows
V1 Minimum | H1 + H2 Maximum | |||
2 - 90º Elbows | Cannot do | |||
back to back | ||||
|
| |||
6 in | 152 mm | 2 | 610 mm | |
1 1/2 ft | 457 mm | 3 ft | 914 mm | |
2 1/2 ft | 762 mm | 5 ft | 1.5 m | |
3 1/2 ft | 1067 mm | 7 ft | 2.1 m | |
|
|
|
| |
4 1/2 ft | 1.4 m | 15 ft | 4.6 m |
V1 + H1+ H2 = 38 ft (11.6 m) Maximum
H1 + H2 = 15 ft (4.6 m) Maximum
H2 | V1 | |
H1 | ||
|
| INSTALLED |
Figure 5.4 | HORIZONTALLY |
|
14 | Heat & Glo • Crescent II • |