Note: The following requirements reference various Massachusetts and national codes not contained in this document.

H. Requirements for the Commonwealth of Massachusetts

For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, in- cluding but not limited to decks and porches, the following requirements shall be satisfied:

Installation of Carbon Monoxide Detectors

At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber or gas fitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed. In addi- tion, the installing plumber or gas fitter shall observe that a battery operated or hard wired carbon monoxide detec- tor with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors.

In the event that the side wall horizontally vented gas fu- eled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.

In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that dur- ing said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed.

Approved Carbon Monoxide Detectors

Each carbon monoxide detector as required in accor- dance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified.

Signage

A metal or plastic identification plate shall be permanent- ly mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fu- eled heating appliance or equipment. The sign shall read, in print size no less than one-half (1/2) inch in size, “GAS

VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB- STRUCTIONS”.

Inspection

The state or local gas inspector of the side wall horizon- tally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector ob- serves carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.08(2)(a)1 through 4.

Exemptions

The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:

The equipment listed in Chapter 10 entitled “Equip- ment Not Required To Be Vented” in the most current edition of NFPA 54 as adopted by the Board; and

Product Approved side wall horizontally vented gas fu- eled equipment installed in a room or structure sep- arate from the dwelling, building or structure used in whole or in part for residential purposes.

MANUFACTURER REQUIREMENTS

Gas Equipment Venting System Provided

When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by the manufacturer for installation of the equipment and the venting system shall include:

Detailed instructions for the installation of the venting system design or the venting system components; and

A complete parts list for the venting system design or venting system.

Gas Equipment Venting System NOT Provided

When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not pro- vide the parts for venting the flue gases, but identifies “special venting systems”, the following requirements shall be satisfied by the manufacturer:

The referenced “special venting system” instructions shall be included with the appliance or equipment in- stallation instructions; and

The “special venting systems” shall be Product Ap- proved by the Board, and the instructions for that sys- tem shall include a parts list and detailed installation instructions.

A copy of all installation instructions for all Product Ap- proved side wall horizontally vented gas fueled equip- ment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation.

See Gas Connection section for additional Common- wealth of Massachusetts requirements.

Heat & Glo • Crescent II • 2083-902 Rev. N • 7/09

5

Page 5
Image 5
Heat & Glo LifeStyle CRESCENT II owner manual Requirements for the Commonwealth of Massachusetts

CRESCENT II specifications

The Heat & Glo LifeStyle CRESCENT II is a remarkable gas fireplace that seamlessly combines elegance and functionality, making it an ideal choice for modern homes. Designed to offer both comfort and aesthetic appeal, this fireplace brings warmth and sophistication to any living space.

One of the main features of the CRESCENT II is its sleek, contemporary design. The fireplace boasts a unique crescent-shaped front that provides an expansive view of the flames, allowing for a captivating visual experience. Its clean lines and minimalistic aesthetic make it a striking centerpiece for both traditional and modern interiors.

Equipped with advanced Intellifire technology, the CRESCENT II ensures a hassle-free experience. This innovative system offers a reliable ignition process, allowing users to start their fireplace with the push of a button. The random flame pattern, an essential characteristic of this model, provides a natural and dynamic fire experience that enhances the ambiance of any room.

The Heat & Glo LifeStyle CRESCENT II also prioritizes efficiency. It features a powerful heating capacity and a balanced flue system that allows for versatile installation options. This makes it suitable for various home layouts while ensuring that heat distribution is optimized. Users can enjoy the cozy warmth of their fireplace without compromising on efficiency or air quality.

With customizable options, homeowners can tailor the firebox to their preferences. Options include different media choices, such as glass, stones, or logs, allowing for personalization that matches individual styles. The CRESCENT II also offers several finish options, from classic to modern, ensuring that it complements the unique décor of every home.

In addition to its aesthetic appeal, the CRESCENT II emphasizes safety and convenience. The fireplace includes features like a safety shut-off system and a tempered glass front, protecting both the occupants and the living environment. The easy-to-use remote control allows users to adjust the flame and heat settings conveniently from any location in the room.

Overall, the Heat & Glo LifeStyle CRESCENT II stands out as a sophisticated and efficient gas fireplace option, offering homeowners the perfect combination of style, technology, and safety. With its thoughtful features and customizable design, it creates an inviting atmosphere that enhances the beauty and comfort of any indoor space.