Heat & Glo LifeStyle ESCAPE-I35-C Minimum Fireplace Size, ESCAPE-I30-C, Location, ESCAPE-I35LP-C

Models: ESCAPE-I35-C

1 49
Download 49 pages 24.38 Kb
Page 19
Image 19
MINIMUM FIREPLACE SIZE

TOP VIEW

A

H

B

G** E

FRONT VIEW

C

D

F

MINIMUM FIREPLACE SIZE

 

 

ESCAPE-I35-C

ESCAPE-I30-C

 

Location

ESCAPE-I35LP-C

ESCAPE-I30LP-C

 

 

 

 

 

 

 

Inches

Millimeters

Inches

Millimeters

 

 

 

 

 

 

A

Rear Width

25-1/2

648

21-1/2

546

 

 

 

 

 

 

B

Front Width

35

889

30-1/4

768

 

 

 

 

 

 

C

Glass Opening Width

31-1/2

800

26-3/4

679

 

 

 

 

 

 

D

Glass Opening Height

20

508

18

457

 

 

 

 

 

 

E

Height-Front

24-7/8

632

22-7/8

581

 

 

 

 

 

 

F

Height-Rear

22-1/4

565

20-5/8

524

 

 

 

 

 

 

G**

Unit Depth

18-1/4

464

16-7/8

429

 

 

 

 

 

 

H

Venting Depth

13-3/8

340

12-1/8

308

 

 

 

 

 

 

*Note: If exhaust collar on insert and fireplace damper do not line up, add 4 inches (102 mm) to minimum fireplace height for bends in vent pipe.

**Unit depth is measured to the back of the surround to give the depth needed for installation.

In addition to these dimensions, also reference

Clearances and Mantel Projections (Section 5.B).

Figure 5.2 Fireplace Opening

Heat & Glo • Escape-I35-C, Escape-I30-C2201-901 Rev. H • 5/12