10 Electrical Information
A. Wiring Requirements
NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA
Code CSA C22.1.
•This appliance comes with a 120 VAC cord assembly. This is required for proper operation of the appliance (Intellifire PlusTM Ignition). An outlet box may be installed in a bottom back corner of the existing solid fuel masonry or factory built fireplace to plug in the cord assembly, or the supplied power cord may be routed out onto the hearth to a nearby outlet.
•A 120 VAC circuit for this product must be protected with
•Low voltage and 120 VAC voltage cannot be shared within the same wall box.
WARNING! Risk of Shock or Explosion! DO NOT wire 120V to the valve or to the appliance wall switch. Incor- rect wiring will damage controls.
B. IntelliFire PlusTM Ignition System Wiring
•Wire an outlet box (120VAC) in the bottom back corner of the existing solid fuel masonry or factory built fireplace to plug in the cord assembly, or the supplied cord assembly may be rerouted out onto the hearth to a nearby outlet for proper operation of the appliance.
WARNING! Risk of Shock or Explosion! DO NOT wire IPI controlled appliance junction box to a switched circuit. Incorrect wiring will override IPI safety lockout.
•Refer to Figure 10.1, IPI Wiring Diagram.
•This appliance is equipped with an IntelliFire PlusTM control valve which operates on a 6 volt system.
•Plug the 6 volt transformer plug into the appliance cord assembly to supply power to the unit OR install 4 AA cell batteries (not included) into the battery tray before use. See Section 2.H for instructions on locating battery tray and installing batteries.
•Battery longevity and performance will be affected by the service temperatures of this appliance. Batteries should only be used as a power source in the event of an emergency such as an outage.
MODULE RESET SWITCH
WIRE ASSEMBLY
TO CORD ASSEMBLY
120VAC
ORANGE
INTERMITTENT PILOT IGNITOR
MODULE ORG |
|
WHT |
|
AUX WIRE EXTENSION | |
| BATTERY PACK |
BLACK | 6V DC (AA X 4) |
| |
GREEN |
|
AUX 300 MODULE
FAN
AUX1 AUX2
RC300 4.5V DC (AAA X 3)
OPTIONAL
AUX2 NOT USED FOR INSERT MODELS. PROTECTIVE COVER INCLUDED.
TO CORD ASSEMBLY
120VAC
(PILOT)
(MAIN) | RED |
| BROWN |
GROUND
EMC FILTER UNIT
LIGHT WIRE ASSEMBLY
EMBER BULB 50W (2)
ACCENT SOCKETS (2)
Figure 10.1 IPI Wiring Diagram
NOTE: SEE FIGURE 10.3 FOR ADDITIONAL INFORMATION