8 Installing Vent Pipe and Appliance

A. Vent Limits

The abbreviations listed in this vent table key are used in the vent diagrams.

Description

Minimum Vertical Run Length 10 ft.

Maximum Vertical Run Length 50 ft.

Horizontal venting is NOT allowed.

Vertical terminations are measured to top of chimney.

This appliance is listed for use with LINK-DV systems and components only. It is permissible to extend venting above existing chimney (within specified maximum verti- cal limits) using SL-D series or Dura Vent GS series 4 in. x 6-5/8 in. gas direct-vent pipe. Connection is made us- ing DV-46DVA-GK. The vent must be terminated with the cap supplied with the LINK-series vent kit.

WARNING! Risk of Fire/Explosion/Asphyxiation! Do NOT connect this gas appliance to a chimney flue serving a separate solid fuel or gas burning appliance.

May impair safe operation of this appliance or other appliances connected to the flue.

Vent this appliance directly outside.

Use separate vent system for this appliance.

CAUTION! ALL vent specifications MUST be followed.

This product is tested and listed to these specifications. Appliance performance will suffer if specifications are not followed.

B. Venting Components

CAUTION! Risk of Cuts/Abrasions/Flying Debris. Wear protective gloves and safety glasses during instal- lation. Sheet metal edges are sharp.

The vertical vent termination system installed on this model includes:

One 3-foot section stainless steel flexible pipe (included with insert).

Flexible vent pipe for exhaust air (included with vent kit).

One length of 3-inch flexible vent pipe for combustion air (included with vent kit).

One pipe-to-cap adaptor (included with vent kit).

One vertical termination cap (included with vent kit).

ADAPTER

V = 10 FT. MINIMUM 50 FT. MAXIMUM

HANDLE

TERMINATION

CAP

INLET

COLLAR

EXHAUST

COLLAR

EXHAUST

AIR

VENT PIPE

INLET AIR

VENT PIPE

INLET AIR STARTING COLLAR

INLET AIR

STARTING

COLLAR

LOCKING TAB

STARTING

COLLAR

BRACKET

EXHAUST

STARTING

COLLAR

NOTE: TO ACHIEVE OPTIMUM PERFORMANCE,

MINIMIZE OR AVOID BENDS IN EXHAUST VENT

PIPE.

STARTING COLLAR BRACKET

EXHAUST STARTING COLLAR

Figure 8.1

Heat & Glo • Escape-I35-C, Escape-I30-C2201-901 Rev. H • 5/12

23

Page 23
Image 23
Heat & Glo LifeStyle ESCAPE-I35-C owner manual Installing Vent Pipe and Appliance, Vent Limits, Venting Components