Heat & Glo LifeStyle ESCAPE-I35-C owner manual J. Before Lighting Fireplace, Module Reset Switch

Models: ESCAPE-I35-C

1 49
Download 49 pages 24.38 Kb
Page 10
Image 10
5.Module Reset Switch

5.Module Reset Switch

This module may lock-out under certain conditions. When this occurs, the appliance will not ignite or respond to commands. The module will go into lock-out mode by emitting three audible beeps, then continuously displaying a RED/GREEN error code at its status indicator LED.

Check battery tray. Remove batteries if installed. Batteries should only be installed for use during power outages. See Section H.

Locate the module reset switch. (See Figure 2.7).

Set the module reset switch to the RESET position.

Wait five (5) minutes to allow possible accumulated gas to clear.

Set the module reset switch to ON.

Start the appliance.

WARNING! Risk of Explosion! DO NOT press the mod- ule reset switch more than one time within a five minute time period. Gas may accumulate in firebox. Call a quali- fied service technician.

MODULE RESET SWITCH

Figure 2.7. Module Reset Switch

Nine Hour Safety Shutdown Feature

This appliance has a safety feature that automatically shuts down the fireplace after 9 hours of continuous operation without receiving a command from the RC300 remote.

J. Before Lighting Fireplace

Before operating this fireplace for the first time, have a qualified technician:

Verify all shipping materials have been removed from inside and/or underneath the firebox.

Review proper placement of logs, ember material and/or other decorative materials.

Check the wiring.

Check the air shutter adjustment.

Ensure that there are no gas leaks.

Ensure that the glass is sealed and in the proper position and that the integral barrier is in place.

WARNING! Risk of Fire/Asphyxiation! DO NOT oper- ate fireplace with fixed glass assembly removed.

This fireplace has an Intellifire PlusTM ignition system.

10

Heat & Glo • Escape-I35-C, Escape-I30-C2201-901 Rev. H • 5/12

Page 10
Image 10
Heat & Glo LifeStyle ESCAPE-I35-C J. Before Lighting Fireplace, Module Reset Switch, Nine Hour Safety Shutdown Feature