D. How to Use the Vent Graph

D. How to Use the Vent Graph

E. Venting Guidelines

1. Measure the distance from the top of appliance to the center of the 90° elbow. On the graph below, draw a horizontal line from that measurement on the vertical axis across until it intersects with the slanted line.

2.From the point of this intersection, draw a vertical line to the bottom of the graph.

3.The point at which this line meets the bottom line of the graph is the maximum length of the horizontal run.

Example 1: If the vertical dimension from the top of the appliance to the center of the 90° elbow is 7 ft. (2m), the horizontal run to the outer wall flange must not exceed 9 ft.-8 in. (3m).

.

Example 2: If the vertical dimension from the top of the appliance is 21 ft. (6m), the horizontal run to the outer wall flange must not exceed 4 ft.-3 in. (1m).

4.Each 90° elbow is equivalent to 3 ft. (914mm) of vent pipe and each 45° elbow is equivalent to 1 ft. (305mm) of vent pipe, and must be subtracted from vent pipe run. A single vertical to horizontal 90° elbow is already calculated into the allowable 15 ft. (5m) run. Each additional 90° elbow reduces the maximum horizontal distance by 3 ft. (914mm).

Example: The use of three elbows would reduce the allowable horizontal run to 9 ft. (3 - 1 = 2 elbows x 3 ft. = 6 ft.; 15 ft. max. - 6 ft. = 9 ft. max.)

Notes:

The maximum horizontal vent run is 15 ft. (5m) when the vertical vent rise is 10 ft. (3m).

Horizontal sections require a 1/4 in. (6mm) rise for every 12 in. (305mm) of horizontal travel.

Exterior vent diameter = 6-5/8 in. (168mm); Inner vent diameter = 4 in. (102mm).

Horizontal sections require noncombustible support every 3 ft. (914mm) , e.g. wall straps.

For any vertical termination a minimum of 6 ft. (2m) vertical must be used.

EXCEPTIONS FOR HORIZONTAL INSTALLATIONS: *The maximum horizontal vent run is 30 in. (762mm).

*The maximum horizontal vent run with a 45° elbow is 18 in. (457mm).

*No external minimum rise is required.

*The minimum horizontal vent run is 6 in. (152mm).

 

 

Termination cap

 

 

 

 

 

25 ft. (8m)

25'

 

 

 

 

 

 

 

NOTE: In the Commonwealth of Mas-

Maximum Vertical

 

 

 

 

 

 

 

sachusetts the word damper shall be

24'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

replaced with the words flue restrictor.

 

22'

 

 

 

 

 

 

 

Example 2

 

 

 

 

 

 

 

 

 

20'

Adjust

 

 

 

 

 

 

 

 

18'

 

 

 

 

 

 

 

 

Intake

 

 

 

 

 

 

 

VERTICAL DISTANCE

16'

Damper

 

 

 

 

 

 

 

FROM APPLIANCE TO

 

 

 

 

 

 

 

 

90° ELBOW

14'

 

 

Install Flue

 

 

 

 

 

12'

 

 

 

 

 

 

 

 

 

Restrictor

 

 

 

 

 

10'

 

 

 

 

 

 

 

 

Example 1

8'

 

 

 

 

 

 

 

Termination cap

 

 

 

 

 

 

 

 

6 ft. (2m) Minimum

6'

 

 

 

 

 

 

 

 

Vertical Termination

4'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2'

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

L

 

2'

4'

6'

8'

10'

12'

14'

15'

 

 

 

 

 

 

SLK-01TRD or an approved Termination Cap

6 in. (152mm) Minimum starter pipe

Figure 5.2

30 in. (762mm) Maximum Horizontal run with no vertical pipe and with 1/4 in. (6mm) rise per foot. Must use approved Termination Cap.

August 1, 2008

Heat & Glo · Tiara Petite B · 7026-101K

Page 11

Page 11
Image 11
Heat & Glo LifeStyle TIARAP-BR D. How to Use the Vent Graph, E. Venting Guidelines, No external minimum rise is required