| Symptom | Possible Cause | Corrective Action |
3. | (Continued) | c. Defective valve. | Turn the valve knob to the ON position. Place the ON/OFF switch in the |
|
|
| ON position. Check the millivolt meter at the thermopile terminals. The |
|
|
| millivolt meter should read greater than 125mV. If the reading is accept- |
|
|
| able, and if the burner does not come on, replace the gas valve. |
|
| d. Plugged burner | Check the burner orifice for stoppage. Remove stoppage. |
|
| orifice. |
|
|
| e. Wall switch or | Follow the corrective action in Symptom and Possible Cause 1.a. |
|
| wires are defective. | Check the switch and wiring. Replace where defective. |
4. | Frequent pilot outage | a. Pilot flame may | Clean and adjust the pilot flame for maximum flame impingement on |
problem. | be too high or too | thermocouple. Follow lighting instructions carefully. | |
|
| low, or blowing |
|
|
| (high), causing safety |
|
|
| pilot to drop out. |
|
5. | The pilot and main | a. No LP in tank. | Check the LP (propane) tank. Refill the fuel tank. |
burner extinguish while | b. Inner vent pipe | Check for proper vent connection at flue collar and all vent joints. | |
in operation. | leaking exhaust |
| |
|
| gases back into the |
|
|
| system. |
|
|
| c. Horizontal vent | The horizontal vent cap should slope down only enough to prevent any |
|
| improperly pitched. | water from entering the appliance. |
|
| d. Bad thermopile or | Replace if necessary. |
|
| thermocouple. |
|
|
| e. Improper vent cap | Check for proper installation and freedom from debris or blockage. |
|
| installation. |
|
6. | Glass soots. | a. Flame impinge- | Adjust the log set so that the flame does not excessively impinge on it. |
|
| ment. | Check that logs are placed according to installation instructions. |
|
| b. Improper shutter | Adjust the air shutter at the base of the burner. |
|
| setting. |
|
|
| c. Debris around | Inspect the opening at the base of the burner. NO MATERIAL SHOULD |
|
| opening at base of | BE PLACED IN THIS OPENING. |
|
| burner. |
|
7. | Flame burns blue | a. Insufficient | Ensure that the vent cap is installed properly and free of debris. Ensure |
and lifts off burner. | oxygen being sup- | that the vent system joints are tight and have no leaks. | |
|
| plied. | Ensure that no debris has been placed at the base of, or in the area of |
|
|
| |
|
|
| the air holes in the center of the base pan beneath the burner. |
|
|
| Ensure that the glass is tightened properly on the appliance, particu- |
|
|
| larly on top corners. |
Page 42 | Heat & Glo · Tiara Petite B · | August 1, 2008 |