Heat Controller RADS-81B TroubleshootingGuide, Unit runs but poor cooling, Troubleshooting Guide

Models: RADS-81B RAD-81A RAD-101A

1 39
Download 39 pages 44.62 Kb
Page 29
Image 29
TroubleshootingGuide

Troubleshooting Guide

Unit runs but poor cooling.Ineffective CoolingManual backgroundTroubleshootingManual backgroundGuideManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

In general, possible trouble is classified in two kinds.

The one is called Starting Failure which is caused from an electrical defect, and the other is ineffective Air Conditioning caused by a defect in the refrigeration circuit and improper application.

Unit runs but poor cooling.

Ineffective Cooling

Check cold air circulation for smooth flow.

Dirty indoor coil (heat exchanger)

Malfunction of fan.

Clogging of air filter.

Obstruction at air outlet.

Remove obstruction.

Check clogging in refrigera- tion circuit.

Repair clogging in refrigeration circuit.

Check outdoor coil (heat exchanger) and fan operation.

Check gas leakage.

Repair gas leak.

Replacement of unit if the unit is beyond repair.

Satisfactory operation with temperature difference of inlet & outlet air; 44~50°F (7~10°C)

Check heat load increase.

Clean condenser.

Not on separate circuit

Check inside gas pressure.

Adjust refrigerant charge.

Malfunction of compressor.

Replacement of compressor.

Service Manual 29

Page 29
Image 29
Heat Controller RADS-81B TroubleshootingGuide, Unit runs but poor cooling, Troubleshooting Guide, Ineffective Cooling