2 x 4 Wall
Fan Housing
2 x 4 wall
1/2 in. (13mm) clearance to combustibles must be maintained.
Sheet Rock
Figure 11.5
Secure
| Bracket |
| Can rotate |
| 180o |
Return Air Grille | Securely Twist |
Install with Louvers | Lock |
pointed down | Adapter |
Figure 11.6
NOTICE: Secure the duct so that clearance to the fireplace outer wrap is maintained. Tape all seams with aluminum tape
9.Seal all the way around the inside of the Return Air Grille to prevent hot air being drawn back into the venting system using gasketing supplied with the kit. Leave 1/4 in. (6mm) clearance from all 4 outer edges. Trim excess gasketing. See Figure 11.7
Leave 1/4" (6mm) clearance from all 4 outer edges
Figure 11.7
10.Install the variable speed wall rheostat (with setting on “OFF”) in a convenient location. This switch will control the
11.Remove the Junction Box. Wire 110 VAC service TO the wall rheostat and FROM the wall rheostat to the fan Junction Box. Use wire nuts to secure the 110 VAC service wires to the hot (black) and neutral (white) fan wires and screw the
110VAC ground wire to the Junction Box. See Figure 11.8.
12.Secure the Return Air Grille to the fan housing making sure it is flush. The grille must be installed with the louvers pointing down.
NOTICE: DO NOT USE ADJUSTABLE REGISTERS.
13.Complete the fireplace installations as per the instruc- tions found in your Owner’s Manual.
Junction Box
White
Black
Wire Nuts
Wire Clamp
Junction Box Removed
Figure 11.8