D. Electrical Access and Wiring Diagram
NOTICE: The manual override switch, rheostat speed con- trol and cover plate are supplied. You will need to supply:
1.Remove junction box cover plate on the bottom right side of the fireplace.
2.Thread the
3.Match colors to wire harness, (red to red, white to white, etc) and secure with wire nuts.
NOTICE: Wiring for fans must be done before framed enclosure is completed. If using a Heat Zone kit, it also must be installed before enclosure is complete.
WARNING! Fire Risk!
Do not apply combustible finishing materials over any part of the front of this fireplace.
•The metal fireplace face may only be covered with noncombustible materials such as ceramic tile, brick, or stone.
•Do not cover or block any cooling air slots.
The decorative fascia must be removable for future service- ability of the Automatic Combustion Control.
•Maintain clearances.
•Use only
•Framing or finishing material used on the front of, or in front of, the appliance closer than the minimums listed, must be constructed entirely of noncombustible materials (i.e., steel studs, concrete board, etc.).
Standard wall mount with
Junction Box
Match colors to wire harness (red to red,
white to white, etc) and secure with a wire nut
Power to the Fireplace
Snap Disc bypass switch
Figure 6.4 Fan Wiring Diagram
WHITE
RED
BLACK
WIRE NUT
WHITE
GREEN BLACK
Incoming Power
(110V)
Warning! Risk of Fire! You must comply with all minimum air space clearances to combustibles. Do NOT pack re-
quired air spaces with insulation or other materials.
WARNING! Fire Risk!
Comply with all minimum clearances specified.
•A minimum 1 in. (13mm) air clearance must be maintained at the back and 1 in. (25mm) to the sides of the fireplace assembly.
•Chimney sections at any level require a 2 in. (51mm) minimum air space clearance between the framing and chimney section.