7 | Appliance Preparation |
|
|
|
|
|
|
|
|
| |
|
|
|
|
| |
| CAUTION |
|
| CAUTION | |
|
|
| Risk of Smoke Spillage | ||
| Sharp Edges |
| |||
|
| Outside air inlet must be located to prevent blockage | |||
| • Wear protective gloves |
| |||
| and safety glasses during |
| from: |
|
|
| installation. |
| • | Leaves | |
|
|
| • | Snow/ice | |
A. Installing Outside Air Kit Damper Assembly |
| • | Other debris | ||
| Blockage may cause combustion air starvation. | ||||
|
|
| |||
|
|
|
|
|
|
WARNING
Fire Risk
Asphyxiation Risk
Maintain vent clearance to combustibles as specified.
•Do not pack air space with insulation or other materials.
•National building codes recommend using attic shield to keep loose materials/ insulation from contacting vent.
Failure to keep insulation or other materials away from vent pipe may cause fire.
This appliance will operate correctly only if adequate ventia- tion is provided to allow proper draft to the system.
An outside air kit is available as an optional feature with this appliance. An outside air kit helps to decrease the amount of room air taken by utilizing outside air for combustion. We strongly recommend that it be installed.
Note: the outside air kit inlet thimble should be positioned in a manner that will not allow snow, leaves, etc. to block the inlet. A 3 ft. (.91 m) minimum height difference must be
Figure 7.1 Outside Air Kit Installation |
| |
NO | NO |
|
Garage or | NO | |
Outlet blocked by | combustible | |
snow, leaves, etc. | liquids storage | Attic space |
|
| NO |
maintained from the top of the uppemost chimney section to the outside combustion air inlet. Reference Section 2.
•The outside air kit can only be installed on the left side of the appliance.
•Refer to the installation instructions provided with the kit.
WARNING
Fire Risk
Asphyxiation Risk
YES
Clear area
outside
house or in
ventilated
crawl space
Outlet placed
higher than 3 ft
below the
termination cap
fireplace
Use only duct materials specified by manufacturer (preferably with short run or mainly straight duct, except small dip for cold air trap which will help prevent flow of cold air).
Do not draw outside combustion air from:
•Wall, floor or ceiling cavity.
•Enclosed space such as an attic or garage.
•Close proximity to exhaust vents or chimneys.
Fumes or odor may result.
Figure 7.2 Outside Combustion Air Placement
16 | Heatilator • Novus |