C. Clearances
Note: If the inside of the framed cavity is to be finished, the framing dimensions must include the finished surface. If drywall is to be attached to the rear wall, the depth must be measured from the drywall surface.
1/2 in.
(13 mm)
1/2 in.
(13 mm)
Drywall
0 in.
Combustible flooring may be installed next to the front of the appliance.
(826 mm) to ceiling
0 in. TO LEVEL OF STANDOFFS
WARNING
Fire Risk
Odor Risk
•Install appliance on hard metal or wood surfaces extending full width and depth of appliance.
•Do NOT install appliance directly on carpeting, vinyl, tile or any combustible material other than wood.
•Do NOT place furniture or any other combustible household objects within 36 in. of the appliance front.
Per
Manufacturer’s
Specifications
Combustible Object
36in.
(914 mm)
| B | |
0 in. | C | |
A | ||
|
|
| A | B | C |
|
| Rough Opening | Rough Opening | Rough Opening |
Model |
| (Width) | (Height) | (Depth) |
|
|
|
| |
NB3630M/MI | in. | 36 | ||
|
|
|
|
|
| mm | 914 | 886 | 498 |
NB3933M/MI | in. | 39 | ||
| mm | 991 | 886 | 498 |
|
|
|
|
|
NB4236M/MI | in. | 42 | ||
| mm | 1067 | 886 | 498 |
|
|
|
|
|
NB4842M/MI | in. | 48 | ||
| mm | 1219 | 886 | 498 |
Figure 3.2 Clearances to Combustibles