Heatiator NB4236MI, NB4842MI, NB3933MI, NB3630MI B. Negative Pressure, Asphyxiation Risk

Models: NB3933M NB3630M NB3630MI NB3933MI NB4236M NB4842MI NB4236MI NB4842M

1 68
Download 68 pages 37.26 Kb
Page 6
Image 6
B. Negative Pressure

B. Negative Pressure

Asphyxiation Risk WARNING

Asphyxiation Risk

Negative pressure can cause spillage of combustion fumes and soot.

Fire needs to draft properly for safe operation.

Draft is the pressure difference needed to vent fireplaces successfully. Considerations for successful draft include:

Preventing negative pressure.

Location of fireplace and chimney.

Negative Pressure

Negative pressure results from the imbalance of air avail- able for the fireplace to operate properly. Causes for this imbalance include:

Exhaust fans (kitchen, bath, etc.).

Range hoods.

Combustion air requirements for furnaces, water heaters and other combustion appliances.

Clothes dryers.

Location of return-air vents to furnace or air conditioning.

Imbalances of the HVAC air handling system.

Upper level air leaks (recessed lighting, attic hatch opening, duct leaks).

To minimize the effects of negative air pressure, the follow- ing must be considered:

Install the outside air kit. Install the intake on the side of the house towards prevailing winds during the heating season.

Ensure adequate outdoor air is supplied for combustion appliances and exhaust equipment.

Ensure furnace and air conditioning return vents are not located in the immediate vicinity of the fireplace.

Avoid installing the fireplace near doors, walkways or small isolated spaces.

Recessed lighting should be a “sealed can” design; attic hatches weather stripped or sealed; attic mounted duct work and air handler joints and seams taped or sealed.

Basement installations should be avoided due to stack effect. Stack effect creates negative pressure in lower levels. Hearth & Home Technologies recommends the use of direct vent fireplaces in basements.

Location of the fireplace and chimney will affect performance. As shown in Figure 2.1 the chimney should:

Be installed through the warm airspace enclosed by the building envelope. This helps to produce more draft, especially during lighting and die-down of the fire.

Penetrate the highest part of the roof. This minimizes the effects of wind turbulence.

Be located away from trees, adjacent structures, uneven roof lines and other obstructions.

Offsets can restrict draft so their use should be minimized. Consider the fireplace location relative to floor and ceiling and attic joists.

 

 

Recommended

Recommended

 

 

Location

 

 

 

Location

 

Location

Marginal

 

 

Location

 

 

Not

 

 

 

 

 

Recommended

 

 

 

 

 

Location

 

 

 

Not

 

 

 

Recommended

 

Windward

 

 

 

Outside Air Intake

Leeward

 

 

Multi-level Roofs

 

 

Figure 2.1 Recommended Chimney Locations

 

6

 

Heatilator • Novus BV-Mesh4031-553 Rev F • 11/07

Page 6
Image 6
Heatiator NB4236MI, NB4842MI, NB3933MI, NB3630MI owner manual B. Negative Pressure, Asphyxiation Risk