Heatiator NB3630MI Symptom, Possible Causes, Corrective Actions, Pilot sparks, but pilot will

Models: NB3933M NB3630M NB3630MI NB3933MI NB4236M NB4842MI NB4236MI NB4842M

1 68
Download 68 pages 37.26 Kb
Page 37
Image 37

 

Symptom

 

Possible Causes

Corrective Actions

4.

Pilot sparks, but pilot will

A.

Correct gas supply.

Verify that incoming gas line ball valve is “open”. Verify that inlet pressure

 

not light.

 

 

reading is within acceptable limits, inlet pressure must not exceed 14 in. w.c.

 

 

B.

Ignitor gap is too large.

Verify that spark gap from ignitor to pilot hood is .17 in. or 1/8 in.

 

 

 

 

 

 

 

C.

Module is not grounded.

Verify module is securely grounded to metal chassis of appliance.

 

 

D.

Module voltage output/

Replace module.

 

 

 

valve/pilot solenoid ohms

 

 

 

 

readings.

 

Heatilator • Novus BV-Mesh4031-553 Rev F • 11/07