E. Junction Box Installation
If the box is being wired from the OUTSIDE of the appli- ance:
•Remove the cover plate located on the outer shell - right side (see Figure 10.3).
•Install the supplied Romex™ connector in the cover plate.
•Feed the necessary length of wire through the connector.
•Make all necessary wire connections and reattach the cover plate to the outer shell.
If the box is being wired from the INSIDE of the appliance:
•Remove the screw attaching the junction box/receptacle to the outer shell, rotate the junction box inward to disengage it from the outer shell (see Figure 10.3).
•Pull the electrical wires from outside the appliance through this opening into the valve compartment.
•Feed the necessary length of wire through the connector.
•Make all necessary wire connections to the junction box/ receptacle and reassemble the junction box/receptacle to the outer shell.
|
| Romex |
|
| Connector |
|
| 14/2WG |
|
| Cover Plate |
|
| outside firebox |
WHT |
|
|
BLK |
| |
WHT | BLK | Copper |
| ||
|
|
GRN wire | ground attached | |
to GRN screw with | ||
inside box | ||
GRN wire | ||
|
Note: Do NOT wire 110
VAC to wall switch.
Figure 10.3 Junction Box Detail
F.Wall Switch Installation for Fan (Op- tional)
If the box is being wired to a wall mounted switch for use with a fan (See Figure 10.4):
•The power supply for the appliance must be brought into a switch box.
•The power can then be supplied from the switch box to the appliance using a minimum of
•At the switch box connect the black (hot) wire and red (switch leg) wire to the wall switch as shown.
•At the appliance connect the black (hot), white (neutral) and green (ground) wires to the junction box as shown.
•Add a 1/4 in. insulated female connector to the red (switch leg) wire, route it through the knockout in the face of the junction box, and connect to the top fan switch connector (1/4 in. male) as shown.
Minimum |
| Switch |
|
| |
with Ground |
|
|
| Red |
|
| Black | Black |
| White | White |
Junction Box | Green | Green |
Red Black White Green |
| Power |
| Switch Box | |
| Supply | |
|
| |
|
| Wires |
| Knockout |
|
Red |
|
|
Figure 10.4 Fan Control Switch Wiring |
|
Heatilator • Novus | 23 |