| Model |
| 1. | Press and hold | for 4 seconds. The “DEF/SET” light | |
|
| flashes in display. |
| |
Temperature Setpoint | 2. | Press the | or | to change the temperature setpoint, |
|
| within 5 seconds. After 5 seconds, the last entered setpoint | ||
|
| stays in memory. |
| |
Other Parameters | 3. | Press | to access the other parameters. Each press of the | |
|
| accesses the next parameter. The parameters are: |
d:differential
LS: lower set; lower
The units are programmed to defrost 3 times a day, at 8 hour intervals, lasting 30 minutes. Do not program the setpoint temperature below 33° F (1° C), or ice
HS: higher set; upper
CA: calibration; temperature readout offset to allow for possible error due to probe location
rP: relay protection; select relay status in case of probe defect. “on” = compressor on in case of probe defect.
“of” = compressor off in case of probe defect
PS: protection
“0”=delay before start - in seconds; “1”=delay before start - in minutes; “2”=delay after stop - in minutes; “3”=delay between starts - in minutes
Pt: protection time; select the time delay setting for compres- sor protection. (0...31 range)
303 |