LOCATION

 

 

 

 

 

 

 

Model CMC/CMR-103,104,105,106,107

2-4.

LOCATION

Place the cold tops in an area where product can be loaded and

 

 

 

unloaded without interruption. For proper operation, level the unit

 

 

 

by adjusting the bolts under the base, and leave 3 feet (91.44 cm)

 

 

 

clearance behind the unit for ventilation and service.

 

 

 

 

For maximum efficiency, units should be operated in an air-condi-

 

 

 

tioned environment, with maximum air temperature of 75° F

 

 

 

(24° C), and 55% relative humidity.

 

 

 

 

 

 

 

Wait at least 4 hours before plugging the unit into an

 

 

 

 

electrical supply. The gases and oils in the refrigeration

 

 

 

 

system needs to settle before operating the compressor, or

 

 

 

 

damage to the compressor could result.

 

2-5.

REFRIGERANT

Refrigerant Type

 

 

Amount of Refrig.

 

Design Pressure

 

 

 

INFORMATION

 

 

 

 

 

 

High

Low

 

 

 

CMC-103

R22

 

 

1.5 lbs (0.680 kg)

 

440psig

162 psig

 

 

 

 

 

 

 

 

 

(30.3 bar)

(11.2 bar)

 

 

 

CMC-104

R22

 

 

1.5 lbs (0.680 kg)

 

440psig

162 psig

 

UL Specs

 

 

 

 

 

 

(30.3 bar)

(11.2 bar)

 

CMC-105

R22

 

 

2.5 lbs (1.134 kg)

 

440psig

162 psig

 

 

 

 

 

 

 

 

 

(30.3 bar)

(11.2 bar)

 

 

 

CMC-106

R22

 

 

2.5 lbs (1.134 kg)

 

440psig

162 psig

 

 

 

 

 

 

 

 

 

(30.3 bar)

(11.2 bar)

 

 

 

CMC-107

R22

 

 

2.5 lbs (1.134 kg)

 

440psig

162 psig

 

 

 

 

 

 

 

 

 

(30.3 bar)

(11.2 bar)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CMC-103

R134A

 

 

1.65 lbs (0.750 kg)

 

440psig

162 psig

 

 

 

 

 

 

 

 

 

(30.3 bar)

(11.2 bar)

 

 

 

CMC-104

R134A

 

 

1.87 lbs (0.850 kg)

 

440psig

162 psig

 

CE Specs

 

 

 

 

 

 

(30.3 bar)

(11.2 bar)

 

CMC-105

R134A

 

 

2.65 lbs (1.200 kg)

 

440psig

162 psig

 

 

 

 

 

 

 

 

 

(30.3 bar)

(11.2 bar)

 

 

 

CMC-106

R134A

 

 

3.09 lbs (1.400 kg)

 

440psig

162 psig

 

 

 

 

 

 

 

 

 

(30.3 bar)

(11.2 bar)

 

 

 

CMC-107

R134A

 

 

3.53 lbs (1.600 kg)

 

440psig

162 psig

 

 

 

 

 

 

 

 

 

(30.3 bar)

(11.2 bar)

2-6.

DRAIN CONNECTION

 

 

 

 

The cold tops-remote (CMRs), requires 1-1/2 inch (38.1 mm)

 

 

 

drain connection. CMCs do not require a plumbed drain.