| Model OFE- 290 |
|
| |
(Continued) |
|
|
High Limit | This high temperature control senses the temperature of the | |
| shortening; if the temperature of the shortening exceeds | |
| 450°F (230°C), this control will open and shut off the heat | |
| to the frypot; when the temperature of the shortening drops | |
| to a safe operation limit, the control must be manually reset by | |
| pressing the red reset button, located under the control panel, in the | |
| right, front of the fryer | |
Figure |
|
|
Filter Drain Pan | The removable pan that houses the filter and catches the shortening | |
| when it is drained from the frypot; also used to remove anddiscard | |
| old shortening | |
|
| When hot shortening is in this pan, use extreme care to |
|
| avoid burns. |
Filter Union | Connects the filter to the filter pump, and allows easy removal of the | |
| filter and drain pan | |
Fuses | A protective device which breaks the circuit when the current | |
| exceeds the rated value | |
To close lid: | ||
| 1. | Lower the lid until latch comes into contact with the pot. |
| To open lid: | |
| 1. | Unlatch the front lid latch. |
| 2. | Lift up on handle to raise lid. |
If the shortening is below 185°F | ||
OPERATION | PUMP switch in the POWER position, the fryer enters the Melt | |
| Cycle. The shortening is heated slowly to prevent scorching of the | |
| shortening. The heat cycles on and off to ensure slow melting of | |
| shortening. At 185°F (85°C) the heat stays on until the Cool Mode | |
| is reached, which is 250°F (121°C). The controls maintains this | |
| temperature until the COOL button is pressed. | |
See Filling andAdding Shortening Section. | ||
| 703 |