3-15. SPECIAL PROGRAM MODE

Model OFE- 290

3-15. SPECIAL PROGRAM MODE

 

 

(Continued)

Factory Presets (F/C, Gas/Electric, Speaker Volume,

 

Speaker Frequency, Codes, Initialize System)

 

1.

Press and hold the FUNCTION button for two seconds until

 

 

“REG PROGRAM” shows in the display. As soon as

 

 

“REG PROGRAM” shows in the display, press and release

 

 

the FUNCTION button 3 times until “FAC PRESET” shows

 

 

in the display.

 

2.

When “CODE” shows on the display, enter 2957. “DEG”

 

 

and “MODE” flashes in the display. Press any of the product

 

 

buttons to toggle from ºF to ºC, and vice versa.

 

3.

Press and release the FUNCTION button and “TYPE”

 

 

and “FRYR” flashes in the display. Press any of the product

 

 

buttons to toggle from “GAS” to “ELEC”, or vice versa.

 

4.

Press and release the FUNCTION button twice, and

 

 

“SPKR” and “VOL” flashes in the display. The volume can

 

 

be changed from 01 to 10, 10 being the loudest.

 

5.

Press and release the FUNCTION button 3 times, and

 

 

“SPKR” and “FREQ” will flash in the display. The frequency

 

 

can be set from 100 to 2000.

 

6.

Press and release the FUNCTION button 10 times, and

 

 

“INITIALIZE SYSTEM” scrolls across the display. Press

 

 

and hold any of the product buttons and the display will count

 

 

down from 5. Once the display counts down, release the

product button, and the control will set factory preset param- eters into the controls.

Before attempting to change the other modes in the Factory

Preset Mode, please call the Henny Penny Technical Service

Department at 1-800-417-8405, or 1-937-456-8405.