Henny Penny OFE- 290 manual TION button. “PROP” and “CONTROL” shows on the

Models: OFE- 290

1 18
Download 18 pages 47.94 Kb
Page 14
Image 14
TION button. “PROP” and “CONTROL” shows on the

Model OFE- 290

3-14. PROGRAMMING

7.

After the load compensation, press and release the FUNC-

(Continued)

 

TION button. “PROP” and “CONTROL” shows on the

 

 

left side of the display and the factory preset proportional

 

 

control temperature shows on the right side of the display.

 

8.

After the proportional control, press and release the

 

 

FUNCTION button. “ALM 1” and “TIME” flashes in the left

 

 

side of the display, and the first alarm time shows on the right

 

 

side of the display. To change the time the alarm sounds,

 

 

press the appropriate product buttons to set the time. Ex:

 

 

Press 1,0,0,0. 10:00 flashes on the right side of the display,

 

 

which means when the timer counts down to 10 minutes, an

 

 

alarm sounds.

 

9.

After alarm is set, press and release the FUNCTION button.

 

 

“ALM 1”, “SELF-’’, and “CANCEL” flashes in the left side

 

 

of the display and “YES” or “NO” shows on the right side of

 

 

the display. The yes and no can be toggled by pressing any of

 

 

the product buttons, (l -0). “YES” means the alarm tone

 

 

automatically stops after several beeps. “NO” means some

 

 

one must manually press the appropriate product button to

 

 

stop the alarm tone.

 

10.

Repeat steps 9 and 10 for alarms 2 and 3.

 

11.

After alarm 3 is set, press and release the FUNCTION

 

 

button. “FILTER” and “CYCLES” show on the left side of

 

 

the display and the Filter Cycle value is on the right side of the

 

 

display. The value is the number of Cook Cycles that must

 

 

completed before the control signals the operator that the

 

 

shortening needs filtered.

 

12.

After the filter value is set, press and release the

 

 

FUNCTION button. “EOC” and “EXIT” flashes on the left

 

 

side of the display and “COOL” shows on the right side of

the display. The end-of-cycle, (EOC), exit point can be set to COOL, SETP, or FLTR, by pressing any of the product buttons (EOC). At the end of a Cook Cycle the controls can be set to return to Cool Mode, the setpoint temperature, or to signal the operator to filter the shortening.