3-11. FILTER PUMP MOTOR PROTECTOR-MANUAL RESET

Model OFE- 290

3-11. FILTER PUMP MOTOR PROTECTOR-MANUAL RESET

3-12. REGULAR MAINTENANCE

The filter pump motor is equipped with a manual reset button, located on the rear of the motor, in case the motor overheats. If motor won’t run, wait about 5 minutes before attempting to reset this protective device to allow motor to cool. Remove the access panel on the left side panel of the unit to reset the button. It takes some effort to reset, and a screwdriver can be used to help reset the button.

To prevent burns caused by splashing shortening, turn the unit’s main power switch to the OFF position before resetting the filter pump motor’s manual reset protection device.

The Henny Penny open fryer does require care and proper mainte- nance. The table below provides a summary of scheduled mainte- nance. The following paragraphs provide step-by-step preventive maintenance procedures to be performed by the operator.

Procedure

Filtering of shortening Changing of shortening Changing the filter envelope Cleaning the frypot Cleaning Nylattrons Lubricate lid rollers

Frequency

See KFC’s Standards Library See KFC’s Standards Library See KFC’s Standards Library See KFC’s Standards Library Monthly-see below Annually-see below

3-13. PREVENTIVE

Cleaning Nylatrons

MAINTENANCE

1.

Spray Henny Penny biodegradable, food safe, foaming

 

 

 

degreaser (part no. 12226) on Nylatrons.

 

2.

Raise lid up and down several times to spread the degreaser.

 

3.

Wipe Nylatrons to remove food soil, grease, and degreaser

 

 

residue.

Lubricating Lid Rollers

The lid rollers, in the back of the fryer, should be lubricated at least once a year, to allow the lid easy movement.

1.Remove the back shroud of the fryer.

2.Using spindle lube, part number 12124, place a small amount of lube on both top and bottom rollers. Make sure to lube both left and right rollers.