Henny Penny OFG, OFE, OGA-341 FILTERING OF SHORTENING Continued, Filter Pump Problem Prevention

Models: OEA OGA-341 OFE OFG

1 22
Download 22 pages 19.08 Kb
Page 16
Image 16
3-9. FILTERING OF SHORTENING (Continued)

Model OFE/OFG/OEA/OGA-341, 342

3-9. FILTERING OF SHORTENING (Continued)

About 10 to 12 filterings can be made with one filter paper envelope, depending on:

the quantity and type of product fried and filtered

the type of breading used

the amount of crumbs left inside the filter drain pan; When the filter screen assembly and filter paper become clogged, and the pumping flow slows, clean

the screen assembly and change the filter envelope.

10.To continue cooking, turn the main power switch to the on position. (Remove the element lift tool on electric fryers.)

3-10. FILTER PUMP PROBLEM PREVENTION

Figure 3-9

3-11. FILTER PUMP MOTOR PROTECTOR – MANUAL RESET

To help prevent filter pump problems:

1.Properly install paper envelope over the filter screens. Fold the open end of the envelope, and clamp with retaining clips so that crumbs cannot enter. (See Figure 3-9)

2.Pump shortening, until no shortening is coming from nozzle.

In the event it overheats, the filter pump motor is equipped with a manual reset button located on the rear of the motor. After waiting 5 minutes to allow the motor to cool, press the reset button. It takes some effort to reset the motor.

A screwdriver can be used to help press reset button.

Servicing of the filter pump is done at the side of the unit. If service is required, disconnect the open fryer from the electricaland/or gas power source.

To prevent burns caused by splashing shortening, turn the unit's filter pump switch to the off position before resetting the filter pump motor’s manual reset protection device.

3-16

903

Page 16
Image 16