Troubleshooting Guide (cont.) |
|
| ||||
|
|
|
| |||
Symptoms | Probable |
| Recommended Action | |||
|
| Causes |
|
|
| |
|
| F. | Sensor |
| F. | Replace the sensor assembly. |
|
|
| eyes are |
|
|
|
|
|
| scratched. |
|
|
|
|
| G. The bleed | G. Turn off the water supply. | |||
|
|
| hole in the |
|
| Remove valve cover and |
|
|
| diaphragm |
|
| diaphragm assembly. Clean any |
|
|
| is plugged |
|
| debris from the area and |
|
|
| or the |
|
| reinstall the components. |
|
|
| plunger is |
|
|
|
|
|
| stuck. |
|
|
|
|
| H. A flex hose | H. Check the flex hoses to make | |||
|
|
| is kinked. |
|
| certain they are not kinked. If |
|
|
|
|
|
| a flex hose is kinked, |
|
|
|
|
|
| disconnect it from the filter |
|
|
|
|
|
| cartridge, straighten, and |
|
|
|
|
|
| reconnect. |
4. | Low flow | A. | Supply |
| A. | Check any filtration systems for |
| (either AC or |
| pressure is |
|
| blockage. Check incoming |
| DC). |
| low. |
|
| water pressure. Pressure should |
|
|
|
|
|
| be at least 20 psi (137 kPa). |
|
| B. | Filters are |
| B. | Turn off water supply and |
|
|
| plugged. |
|
| disconnect fittings from supply |
|
|
|
|
|
| lines. Remove filter cartridges |
|
|
|
|
|
| from both supply lines. Clean |
|
|
|
|
|
| debris from screens and |
|
|
|
|
|
| reinstall the cartridges. |
|
| C. | Aerator is |
| C. | Remove the aerator and clean |
|
|
| plugged. |
|
| it. For calcium/mineral |
|
|
|
|
|
| deposits, soak the aerator |
|
|
|
|
|
| plastic insert in a 50:50 mixture |
|
|
|
|
|
| of vinegar and water. Soak only |
|
|
|
|
|
| the insert and no other |
|
|
|
|
|
| components. |
5. | Constant | A. | Battery life |
| A. | Remove spout and replace |
| water flow |
| expired. |
|
| battery. Use a standard 6 Volt |
| (DC). |
|
|
|
| lithium battery. This item is not |
|
|
|
|
|
| available from Kohler but can |
|
|
|
|
|
| be purchased at many stores |
|
|
|
|
|
| locally. |
6. | Constant | A. | The power |
| A. | Once the power is stable, |
| water flow |
| source is |
|
| unplug the unit and plug back |
| (AC). |
| unstable, |
|
| into wall. |
|
|
| off, or the |
|
|
|
|
|
| circuit is |
|
|
|
|
|
| blown. |
|
|
|
|
|
|
|
|
| |
|
|
|
|
| ||
Kohler Co. |
| 21 |
|