Kohler k-10951 Troubleshooting Guide cont, D. The, Symptoms, Probable, Recommended Action, Causes

Models: k-10951 k-10950

1 76
Download 76 pages 28.62 Kb
Page 19
Image 19
Troubleshooting Guide (cont.)

Troubleshooting Guide (cont.)

 

 

 

 

 

 

Symptoms

Probable

 

Recommended Action

 

Causes

 

 

 

 

C.

There is

 

C.

Remove the spout and check

 

 

water

 

 

for corrosion on the

 

 

leakage on

 

 

connections between the battery

 

 

electrical

 

 

to solenoid and the solenoid to

 

 

components

 

 

sensor. If possible, clean the

 

 

or

 

 

terminals. If unable to repair

 

 

connectors.

 

 

the connection, order a new

 

 

 

 

 

sensor assembly or solenoid

 

 

 

 

 

assembly, as required. Inspect

 

 

 

 

 

the O-ring on the valve for

 

 

 

 

 

cuts, debris, etc. If the O-ring is

 

 

 

 

 

damaged, order a new O-ring.

 

 

 

 

 

The origin of the leak must be

 

 

 

 

 

investigated and repaired.

 

D. The

 

D. Remove the spout and replace

 

 

battery life

 

 

the battery. The spout requires

 

 

has

 

 

a standard 6 Volt lithium

 

 

expired.

 

 

battery. This item is not

 

 

 

 

 

available from Kohler but can

 

 

 

 

 

be purchased at many stores

 

 

 

 

 

locally.

2. No water

A.

The AC

 

A.

Plug the AC wall brick firmly

flow (AC).

 

unit is not

 

 

into a working outlet.

 

 

plugged

 

 

 

 

 

in.

 

 

 

 

B.

The

 

B.

Check that the breaker for the

 

 

ground

 

 

circuit used by the faucet is on.

 

 

fault

 

 

 

 

 

breaker is

 

 

 

 

 

tripped.

 

 

 

 

C.

There is a

C.

Remove the spout and check

 

 

loose

 

 

the connection from the AC

 

 

connection.

 

 

unit to the solenoid and from

 

 

 

 

 

the solenoid to sensor. Make

 

 

 

 

 

sure that the connector arrows

 

 

 

 

 

are aligned and that the

 

 

 

 

 

connection is secure.

 

D. The wires

D. Remove the spout and verify

 

 

are

 

 

that the wires are tucked inside

 

 

pinched or

 

 

the spout before reassembling.

 

 

damaged.

 

 

If wires are cut or damaged,

 

 

 

 

 

order new solenoid or sensor

 

 

 

 

 

assembly.

 

 

 

 

 

 

 

 

 

 

 