Kohler k-10951, k-10950 manual Service the Battery

Models: k-10951 k-10950

1 76
Download 76 pages 28.62 Kb
Page 7
Image 7
Service the Battery

Sensor

 

 

Connector

Battery

Position 2

Connector

 

Connector

Position 1

Valve

Battery Clip

 

Service the Battery

CAUTION: Risk of product damage. Separate the connectors by pulling gently while holding onto each connector. Do not

pull apart by the wires.

Perform the steps in the ″Disassemble the Faucet″ section.

Pull up on the spout to separate it from the valve.

Disconnect the battery connectors by pulling gently on both connectors.

Reach inside the faucet body and gently pull the end of the battery clip up until it comes free from the two tabs.

Pull the battery and battery clip out of the faucet body.

Remove the battery from the battery clip.

Install a new battery into the battery clip.

If the sensor clip comes out with the battery clip, reinstall it according to the steps in the ″Replace the Sensor ″ section.

Continue to the ″Reinstall the Battery Clip - DC Models Only″ section.

Kohler Co.

7

1025498-5-H

Page 7
Image 7
Kohler k-10951, k-10950 manual Service the Battery