Troubleshooting Guide (cont.) |
|
| |||
|
|
| |||
Symptoms | Probable | Recommended Action | |||
|
| Causes |
|
| |
7. | Constant | A. | The | A. | Turn off the water supply and |
| water flow |
| diaphragm |
| purge the faucet. Remove the |
| (Either AC or |
| seal dirty |
| valve front plate and check the |
| DC). |
| or |
| diaphragm and surrounding |
|
|
| damaged. |
| area for debris. Clean out any |
|
|
|
|
| debris. If the diaphragm is |
|
|
|
|
| damaged, order a replacement. |
|
| B. | The | B. | Remove the spout and |
|
|
| solenoid is |
| solenoid. Check the solenoid |
|
|
| plugged. |
| holes for debris. |
|
| C. | The | C. | Remove the spout and |
|
|
| solenoid is |
| solenoid. Replace the solenoid. |
|
|
| does not |
|
|
|
|
| work. |
|
|
|
| D. The | D. Turn off the water supply and | ||
|
|
| filter(s) are |
| disconnect the fittings from the |
|
|
| plugged. |
| flex hoses. Remove the filter |
|
|
|
|
| cartridges from both supplies. |
|
|
|
|
| Clean all debris from the |
|
|
|
|
| screens and replace them in the |
|
|
|
|
| unit. |
8. | Sporadic | A. | The faucet | A. | Verify that the faucet is |
| water flow. |
| is installed |
| mounted flat to the deck |
|
|
| at wrong |
| surface and that the sensor eyes |
|
|
| angle to |
| are aligned to the user area. |
|
|
| deck or |
| Ensure that the faucet is |
|
|
| misaligned |
| installed in a position that is |
|
|
| with user |
| above the rim of the lavatory. |
|
|
| area. |
|
|
|
| B. | The wires | B. | Remove the spout and verify |
|
|
| are |
| that the wires are tucked inside |
|
|
| pinched or |
| the spout before reassembling. |
|
|
| damaged. |
|
|
9. | Water is | A. | The valve | A. | Order a new |
| dripping on |
|
| valve and install. | |
| deck |
| missing, |
|
|
|
|
| cut, or |
|
|
|
|
| damaged. |
|
|
|
|
|
|
| |
|
|
|
|
| |
|
| 22 | Kohler Co. |