CHAPTER 2

Setup and Configuration

Installing a Line Cord Cap - U.K. Only

In the United Kingdom, core colours in the mains lead of this equipment may not correspond with the colored markings identifying the terminals in the fixture’s plug. In that case, install a line cord cap according to the following code:

Connect the green and yellow core to the plug terminal marked with the letter “E,” or by the earth symbol or coloured green, or green and yellow.

Connect the blue core to the terminal marked with the letter “N” or coloured black.

Connect the brown core to the terminal marked with the letter “L” or coloured red.

WARNING:

Class 1 equipment - This equipment must be earthed.

Vatic Fitter Heads Information - Danmark

Advarsel: Beskyttelse mod elektrisk chock.

Vigtigt!

Lederne med gul/groen isolation maa kun tilsluttes en klemme maerket

eller

 

Mounting the Fixture

You can mount your StudioPix™ fixture suspended from a support system (such as a truss) or freestanding on its base.

WARNING!

Equipment suitable for dry locations only. Do not expose this equipment to rain or moisture.

CAUTION!

Always use a secondary safety cable when mounting this fixture. This fixture must be installed and operated by trained personnel only.

 

1

m

Maintain a minimum focus distance of 1 meter from a lighted object.

 

 

 

 

 

Note:

Due to the wide variety of possible lighting designs, High End

 

 

 

Systems cannot make specific mounting recommendations. Consider

 

 

 

the following procedure as a suggested guideline only.

Mounting the Fixture Upright

CAUTION!

Do not mount the fixture upright without the four rubber feet attached.

To mount the fixture upright, place the fixture on a sturdy, stable non-flammable surface that will support more than the 20.9 kg (46 lb) weight of the StudioPix™ fixture. If the surface is above floor height, use safety cables to secure the fixture to the surface.

8

StudioPix™ Pixelation Luminaire User Manual

Page 22
Image 22
High End Systems Pixelation Luminaire user manual Mounting the Fixture, Installing a Line Cord Cap U.K. Only