Useful Feature

Useful Feature

Eco Operation

In the eco operation mode, the unit automatically pauses when the air in the room is clean to save money on electricity. Furthermore, if this state continues more than 8 hours, the unit automatically stops operation. (In humidifying operations, the unit will not pause at a certain humidity level.)

Normal automatic operation

 

When the air is clean, the unit continuously operates at

Silent

“Silent” airflow. (In the strong deodorization mode, the

operation

airflow rate is set to “Low”.)

Stop

 

Eco operation

10 minutes

10 minutes

10 minutes

When the air is clean and “Silent” operation continues

for 10 minutes or longer, the fan stops for about 50

Silent

 

 

 

minutes and the unit intermittently operates at “Silent”

 

 

 

airflow for about 10 minutes.

operation

 

50 minutes

50 minutes

If this state continues more than 8 hours, the unit

Stop

 

 

 

automatically stops operation.

 

 

 

 

The degree of air contamination is detected by the odor sensor and dust sensor during eco operation. If the sensors detect odor or dust, the airflow rate switches according to the degree of air contamination. When the air becomes clearer and the unit runs for 10 consecutive minutes or longer at “Silent” airflow, the unit starts intermittent operation.

 

“eco” indicator is lit.

 

Press

button.

Pollen

Strong

Skin

 

Air Purify

Deodorization

Humidify Moisturize

 

On

Max(Blinking)

Auto

 

 

 

The mode is set to eco operation.

How to set/cancel

Every time you press

button, "Set" and

"Cancel" will alternate.

Eco Operation The settings are stored.

Note

Dimmer Control When using the air purifier together with the Hitachi air purifier with ionizing function

Pressing the Press  button for 3 seconds or longer. button on the remote controller in front of the Hitachi air purifier with ionizing function (model whose

ionization setting / release is switched using the remote controller) sets and releases ionization. Furthermore, pressing the ionizing button on the remote controller of the model with the ionizing function sets and releases eco operation.

Dimmer Control

If you feel uncomfortable about indicator lightings when you go to sleep, press Manual background button on the purifier unit for 3 seconds or longer to dim the indicators.

Press Manual background button for 3 seconds or longer.

The indicators are dimmed.

How to set/cancel

Every time you press Manual background button, “Set” and “Cancel” will alternate.

The setting will be saved in memory.

Memory Function / Sensors / Auto Detection Useful Feature

E-17

Page 17
Image 17
Hitachi EP-A7000 Useful Feature, Eco Operation, Dimmer Control, Press button for 3 seconds or longer, How to set/cancel