<ID/TITLE Setup Procedure>

ŒWith the cursor located at DATA SET, press the D button. The cursor moves to the ID data set position an the first character flashes.

Using the L, R, U and D buttons, select an input character.

ŽPress the SET UP button, and the selected character will be entered. (The cursor will then move to the next character position.)

In the same manner, repeat the above steps ￿ and ￿ to enter an ID code and TITLE.

On completion of character input, bring the cursor to RET using the L, R, U or D button. Then, press the SET UP button.

The cursor is returned to DATA SET.

To quit the SPECIAL SET mode, press the SET UP button.

:Flashing shifts one character toward the left.

:Flashing shifts one character toward the right.

DEL: Flashing character is deleted, and the subsequent character string is shifted left.

INS : A space is inserted at the flashing character position, and the subsequent character string is shifted

right.

RET : The cursor is returned to DATA SET.

14. DTL

Menu for setting detail parameters

1) LEVEL DEP: Dependent level setting

Detail amount, and noise, can be reduced in scene dark components.

Setting range is -128 to +127. Press the R button to increase the value, reduce the detail amount and expand

the video signal level range. Press L button to decrease the value and reduce the range. Set to 0 by

simultaneously pressing the L and R buttons for about 2 seconds.

2) CRISP: Crispness level setting

Reduces noise when DTL setting is in the range of -128 to 127. However, at high settings, some loss of sharpness occurs in detailed scene components. Setting range is -128 to +127. Press the R button to increase the value and the detail noise. Press the L button to decrease the value and reduce detail noise. Set to 0 by simultaneously pressing the L and R buttons for about 2 seconds.

3) H/V BALANCE: Balance setting for horizontal and vertical detail amount

Setting range is -128 to +127. Press the R button to increase the value and reduce the H DTL amount. Press the L button to decrease the value and reduce the V DTL amount. Set to 0 by simultaneously pressing the L and R buttons for about 2 seconds.

4)INITIALIZE: Return each item to factory settings by simultaneously pressing the L and R buttons for about 2 seconds.

29

Page 42
Image 42
Hitachi HV-D25 operation manual Dtl